Battery Manufacturing Equipment
EQUIPMENT • MODULE & PACK

ACEY-SP1200 prismatic module stacking and compression station

ACEY-SP1200 lines up finished prismatic cells and compresses them before the module is strapped. A servo motor and planetary reducer drive a screw module over a 1200 mm stroke, with a 500 KG maximum load setting. It handles cells 50–250 mm long and suits module assembly after cell production.

By Xiamen Acey New Energy Technology Co., Ltd. · ACEY-SP1200

BatteryEquip editorial teamSource review: 2026-10-11Buying guide based on the maker's published data.
PUBLISHED REFERENCE

Where it sits: module assembly

ACEY describes a screw module driven by a servo motor through a planetary reducer, with a pressure controller and live stroke and force settings. The table gives a 1200 mm extrusion stroke and a cell range of 50–250 mm length, 20–100 mm width and 100–300 mm height. Tell ACEY how your cells will be oriented and ask which machine axis matches each cell dimension, and whether your full module fits within the compression travel.

The introduction mentions stacking, pressing and bundling. Automatic loading and the exact strapping tools are not described. Ask for an operating sequence from loose cells to a restrained module that marks every manual step, separator, end plate and strap. Cell sorting before the press and busbar welding after it are separate machines in ACEY's range.

Original parameter values · 7 entries
ParameterPublished valueRecord status
Published extrusion stroke1200 mmknown
Cell length envelope50–250 mmknown
Cell width envelope20–100 mmknown
Cell height envelope100–300 mmknown
Listed power1 kWknown
Published reference dimensions2370 × 500 × 1400 mmknown
Listed mass400 kgknown

Catalogue values apply to the configuration and test method the maker states. Ask for the values that apply to your configuration.

Source references: s1

BUYER NOTES

Force units and safe cell loading

The page gives a maximum stacking load of 500 KG with a control error of 0.1 KG, while the introduction says more than 500 KG. Both use mass units for a force. Ask ACEY to state the force in newtons or another defined unit, together with the sensor range, calibration and the allowed working load.

Your cell maker's compression limits should set the fixture design. Check platen contact, end-plate stiffness, room for cell swelling and how load spreads across the cell faces. Ask ACEY to show its software limits, hardware limits and load threshold working, including recovery after a stop. Watch how the press reacts to a wrong force setting before it touches real cells.

Source references: s1

BUYER NOTES

Accept the compressed module, not just a press cycle

ACEY gives an example of 50 groups per hour with ten cells per group and a 'grafting rate' of at least 98%. Ask ACEY to define 'grafting rate', and treat both figures as examples until your own module has run. Time a trial covering cell loading, separators, pressing, strapping and removal. Set accepted module dimensions and decide whether to measure relaxation after the press releases.

ACEY lists 1 kW at AC 220 V/50 Hz, no compressed air, dimensions of 2370 × 500 × 1400 mm and a mass of 400 kg. Plan working space around that footprint for cell handling and strap installation. If several cell lengths or module layouts will share the press, ask for a format change demonstration and stored recipes. Positioning accuracy matters most where cells must line up for the later busbar step.

Source references: s1

MAKE A SELECTION

Questions that change the purchase

DecisionWhat the catalogue saysNext step
Does the complete module fit?The page lists cells of 50–250 × 20–100 × 100–300 mm and a 1200 mm stroke.Approve a module drawing showing orientation, end plates and strap access.
What load is safe and measurable?The page gives a 500 KG maximum and also says more than 500 KG.Get the force unit in writing and check it against your cell maker's limits.
What is the accepted production cycle?The page gives 50 groups per hour of ten cells as an example.Time loading through strap removal and measure the finished module.
CLEAR UP THE DETAIL

Equipment questions

Does 'stacking' mean building electrodes inside a cell?

No. SP1200 stacks cells that are already sealed in their cases into a module. Electrode stacking, separator placement, electrolyte filling and cell sealing happen earlier, on cell-making machines.

Source s1
FROM READING TO A BRIEF

Prepare the supplier conversation

Fill in the conditions below and ask the supplier to answer each open point in writing. Copying or downloading stays in your browser; nothing is sent.

Prepare a full project brief →

SOURCES

Sources and check dates

The maker's own pages and public records used for this page, each with the date it was checked.

s1 · ACEY-SP1200 prismatic module stacking and compression station — manufacturer equipment page

ACEY · Manufacturer-origin source

ACEY's product page with drive design, stroke, cell size range, load figures, example output and utilities.

Archived source check: 2026-10-11

s2 · ACEY official equipment portfolio

ACEY · Manufacturer-origin source

ACEY's pack-line range, including sorters before the press and welders after it.

Archived source check: 2026-10-11

Still to confirm

  • The force unit behind the 500 KG load and 0.1 KG control error, and the allowed working load for your cells.
  • What 'grafting rate' means and how the 98% figure is measured.
  • Which bundling tools and handling steps are automatic on the delivered station.
  • Accepted module dimensions and cycle time on your own cells.
BEFORE YOU REQUEST A QUOTE

Finished prismatic-cell module stacking, compression and bundling preparation

  1. Cell drawing and cell maker's compression limits
  2. Module cell count, separators and end plates
  3. Force units, calibration and limit demonstration
  4. Strapping tools and manual or automatic handling steps
  5. Released-module dimensions, changeover and timed trial
Edit your enquiryRead the manufacturer dossier →
Analytics preferences

Usage analytics loads only with your consent. Private pages are excluded. Inquiry text and contact details are not sent to analytics.

Analytics has not been allowed.