Hangke formation-restraint loading and release equipment
Hangke's restraint loading and release machine fits and removes the fixtures that hold cells under force during formation. Hangke lists automatic installation and removal, quick changeover, high-precision loading and a restraint force of 0–15 T. It works alongside formation systems on prismatic and other cells that are formed under pressure.
The 0–15 T force figure and what it leaves open
Hangke gives the force in T, without saying whether that means tonne-force, under what calibration conditions or over what contact area. Ask for an engineering definition of the unit. Pressure on each cell depends on contact area and load spread, so ask for a pressure figure per cell for your fixture. Hangke mentions high-precision loading without a control accuracy figure.
Send the cell and restraint drawings, occupied positions, contact areas and the allowed deformation. Specify the load or displacement sequence and the signal that confirms a fixture is correctly engaged. Ask whether the machine works with your existing trays, airbags or formation equipment, and what interface work that needs.
| Parameter | Published value | Record status |
|---|---|---|
| Published restraint-force range | 0–15 T | known |
Catalogue values apply to the configuration and test method the maker states. Ask for the values that apply to your configuration.
Source references: s1
Linking the restraint state to the formation recipe
Agree how fixture ID, cell and tray ID and load state are checked before the electrical process starts. Decide which system sets the required restraint force and whether the result is measured by a load sensor or taken from actuator position. Hangke publishes no feedback design or data interface, so request both.
Watch load application and release on the approved fixture, checked against calibrated force references. Inspect cells and contact areas against the agreed damage and deformation limits. Include a half-engaged fixture or wrong-fixture case defined by Hangke. When demonstrating quick changeover, check that the recipe and tool are verified as well as swapped quickly.
Stored force, release and recovery
Ask for the operating and isolation sequence that decides when the restraint may open and when a cell may move. After a fault or power loss the fixture may still hold force, so ask Hangke whether the machine holds or releases in that case and how. Review that logic together with the electrical state of the formation equipment.
At handover, get the wear and contact surfaces, load-sensor calibration, maintenance access and recovery steps for fixtures left half-fitted or half-released. Hangke states no cell rate, pressure spread or effect on cell performance, so set the force for your cell design in the specification. Base acceptance on the delivered restraint and its interfaces.
Hangke's profile lists the formation systems this station serves, such as the Hangke prismatic negative-pressure formation system, and the page on formation and grading explains why restraint force matters during the first charge. The acceptance testing page covers how to verify force on a full tray, and the RFQ guide lists how to request the force definition.
Source references: s1
Questions that change the purchase
| Decision | What the catalogue says | Next step |
|---|---|---|
| What does T mean in the delivered force specification? | The catalogue gives 0–15 T with no unit definition or calibration conditions. | Get a signed force definition, sensor method and fixture drawing. |
| How is engagement verified before formation? | The catalogue describes automatic fitting and no feedback design. | Specify fixture and cell ID checks and a measured hold state. |
| When can stored force be released? | The catalogue does not describe fault or isolation recovery. | Review the release sequence together with the formation electrical state. |
Prepare the supplier conversation
Fill in the conditions below and ask the supplier to answer each open point in writing. Copying or downloading stays in your browser; nothing is sent.
Sources and check dates
The maker's own pages and public records used for this page, each with the date it was checked.
s1 · Hangke formation-restraint loading and release equipment original public data
Hangke Technology · Manufacturer-origin source
Describes automatic restraint fitting and removal, quick changeover and the 0–15 T force range.
Archived source check: 2026-10-11
s2 · Hangke original post-processing equipment portfolio
Hangke Technology · Manufacturer-origin source
Shows the restraint machine alongside Hangke's formation systems.
Archived source check: 2026-10-11
Still to confirm
- What the T unit means, with calibration conditions and contact area.
- Force control accuracy and pressure spread across cells.
- Cycle rate and the data interface to the formation system.
- Whether the fixture holds or releases force after a fault or power loss.
Automatic fitting and release of formation restraint fixtures
- Cell and restraint geometry and contact area
- Force unit, load or displacement sequence and feedback
- Deformation and damage limits and calibrated fixture trials
- Fixture and recipe identity and formation hand-off
- Stored-force isolation and half-finished recovery
- Changeover checks, wear surfaces and calibration