Battery Manufacturing Equipment
EQUIPMENT • CALENDERING

JS100L-LX heated laboratory roll-to-roll calender

The TOB-JS100L-LX is a compact heated roll press for lab electrodes, with two 96 mm rolls heated up to 130°C and a 0–2 mm gap. The model table gives 100 mm cold and 80 mm hot pressing width, while the introduction says 200 mm and 180 mm. Pressure display is an option. It suits labs densifying small electrode samples.

By Xiamen TOB New Energy Technology Co., Ltd. · TOB-JS100L-LX

BatteryEquip editorial teamSource review: 2026-10-11Buying guide based on the maker's published data.
PUBLISHED REFERENCE

Confirm the pressing width first

The introduction on TOB's page gives 200 mm cold and 180 mm hot pressing widths. The TOB-JS100L-LX table gives 100 mm cold and 80 mm hot, with two rollers of 96 mm diameter. Ask TOB to confirm the usable width for the rollers in your quotation before you rely on either pair of figures.

The table lists roll temperature from room temperature to 130°C, a pressing-thickness setting of 0–2 mm and working speed of 0–40 mm/s. Power is 800 W and the machine measures about 800 × 700 × 350 mm. Ask for a drawing of the configuration you will receive and check these settings in a trial.

Original parameter values · 5 entries
ParameterPublished valueRecord status
Roller diameter, model table96 mmknown
Roll temperature, catalogueRT to 130 °Cknown
Pressing-thickness setting0–2 mmknown
Working speed0–40 mm/sknown
Electrical power800 Wknown

Catalogue values apply to the configuration and test method the maker states. Ask for the values that apply to your configuration.

Source references: s1

BUYER NOTES

Order pressure display if you need it

TOB notes that its standard quotation leaves out real-time pressure display unless you request it. If your lab records need force or pressure, ask which sensor is supplied, where it measures and how its reading relates to the force at the nip.

Roll gap, displayed pressure and final electrode thickness are three different quantities. Measure incoming and outgoing thickness and record the method, rather than reading the result off a gap setting.

Source references: s1

BUYER NOTES

Trial at your target temperature

Use your own electrode coating and current collector to check adhesion, density and damage after pressing. Record upper and lower roll temperature if shown, material speed, gap setting and web handling. Inspect across the usable width and along the pressed sample.

If roll-to-roll handling is part of the order, check core sizes, unwind and rewind limits and how tension is controlled. This is a compact lab press, so ask exactly which web-control parts come with it.

Buying guidance from BatteryEquip.

MAKE A SELECTION

Questions that change the purchase

DecisionWhat the catalogue saysNext step
What is the usable width?The page gives 200/180 mm in the introduction and 100/80 mm in the model table.Get a dated JS100L-LX drawing with cold and heated usable widths.
Do you need pressure readings?The standard quotation leaves out real-time pressure display unless requested.List the sensor, what it reads and its calibration record if you need pressure data.
Does the pressed electrode hit target?The catalogue gives gap and temperature settings with no density or adhesion results.Press your electrode and measure the finished web at agreed positions.
CLEAR UP THE DETAIL

Equipment questions

Which width should I buy against?

Use the figure TOB confirms on a dated drawing for the rollers it quotes. Ask for cold and heated usable widths separately, and attach them to your enquiry and trial record.

Source s1
FROM READING TO A BRIEF

Prepare the supplier conversation

Fill in the conditions below and ask the supplier to answer each open point in writing. Copying or downloading stays in your browser; nothing is sent.

Prepare a full project brief →

SOURCES

Sources and check dates

The maker's own pages and public records used for this page, each with the date it was checked.

s1 · JS100L-LX heated laboratory roll-to-roll calender — original equipment page

TOB · Manufacturer-origin source

TOB's product page for the JS100L-LX, with roll size, width figures, temperature, gap, speed, power, size and the pressure display note.

Archived source check: 2026-10-11

s2 · TOB equipment catalogue

TOB · Manufacturer-origin source

TOB's equipment catalogue, listing this press with its other calenders.

Archived source check: 2026-10-11

Still to confirm

  • The usable cold and hot width: 200/180 mm or 100/80 mm.
  • Whether pressure display and its sensor are included in your quotation.
  • Which unwind, rewind and tension parts are supplied.
  • Thickness and density results on your electrode.
BEFORE YOU REQUEST A QUOTE

Heated lab calendering of electrode sheets and short rolls

  1. Confirmed cold and hot usable roll widths
  2. Incoming electrode thickness and density target
  3. Roll temperature and working speed range
  4. Pressure display and sensor needs
  5. Unwind, rewind, core and tension control
Edit your enquiryRead the manufacturer dossier →
Analytics preferences

Usage analytics loads only with your consent. Private pages are excluded. Inquiry text and contact details are not sent to analytics.

Analytics has not been allowed.