Battery Manufacturing Equipment
EQUIPMENT • CELL ASSEMBLY

Cell airtightness detection machine

Shuangren's cell airtightness detection machine sits in its prismatic power and storage cell finishing range, next to helium charging, plug handling and ball sealing. The listing gives no model, test pressure, leak limit or cycle time, so a quote should start with the test method and the cell's sealing state.

By SHUANGREN

BatteryEquip editorial teamSource review: 2026-10-11Buying guide based on the maker's published data.
PUBLISHED REFERENCE

What the listing gives and what to ask for

Shuangren lists an airtightness detection machine in its cell finishing range. The listing has no fixed model, test pressure, leak limit, sensitivity or cycle time. Shuangren sells helium charging stations as separate items, so ask whether this tester uses helium mass spectrometry or another sensing method.

Ask the supplier for the sensing method and the state of the cell at test. A temporary closure, a final seal and a gas-filled cell are three different conditions. Request the fixture, the test sequence, the reference-leak or reference-part method and the units used for acceptance, and only then talk about a leak-rate figure.

Original parameter values · 3 entries
ParameterPublished valueRecord status
Equipment typeAirtightness detection machine known
Catalogue positionPrismatic/power and energy-storage cell equipment series known
Related operationsHelium charging, sealing, restraint handling and wrapping listed in the catalogue known

Catalogue values apply to the configuration and test method the maker states. Ask for the values that apply to your configuration.

Source references: s2

BUYER NOTES

Make sealing and testing duties explicit

Send cell drawings, the sealing state, the test gas you allow and the defect criterion you need. Ask which upstream station prepares the cell and how the tester rejects or passes it. If helium charging and plug insertion are in the scope, show on the process map how they connect to the detection step.

The trial should include repeat tests on known reference parts and a plan for dealing with fixture leaks. Settle changeover, calibration and the result saved against each cell ID. The category name tells you what kind of machine it is; the trial tells you whether it suits your cell.

Buying guidance from BatteryEquip.

BUYER NOTES

Write the leak-test method into the quote

Before choosing a threshold, ask the supplier to state the measuring principle, test medium, part preparation, fixture and ambient conditions. The approved procedure should describe the pressure sequence and the stabilisation and measurement periods. Because helium appears elsewhere in the range, ask for the detector type and sensitivity of this tester in particular. Your cell engineering team should approve the test conditions the cell can safely take.

Agree reference artefacts and challenge samples, approved by the supplier, for the repeatability and rejection demonstrations. Log the fixture ID, reference status and settings with each result. Ask how the machine tells temperature drift, fixture leakage and a poor seal apart from a faulty cell. Collect calibration and maintenance documents for the chosen method. Choose gas, pressure and any destructive checks together with Shuangren for your specific cell.

Buying guidance from BatteryEquip.

BUYER NOTES

Judge borderline parts and retests under one written method

Get the sensing principle, test units, pressure conditions and stabilisation sequence in writing. A leak-limit number means little until those conditions and the cell's state are known. Agree suitable reference parts or reference leaks with the supplier and your quality team before any demonstration.

Look at repeat measurements, a known failing condition and an interrupted run, all under that same method. Ask how the machine separates fixture leakage from the cell result and how retests are logged. Ask Shuangren to state the method, sensitivity and cycle time for this machine in the quotation.

The Hangke helium leak-check station shows how a helium method is specified, which is useful for comparison when the test method of this machine is confirmed.

Source references: s2

MAKE A SELECTION

Questions that change the purchase

DecisionWhat the catalogue saysNext step
Which leak-test method is proposed?The listing names the machine with no method, pressure or threshold.Request the medium, pressure sequence, detection principle and calibrated reference.
How will repeatability be accepted?The listing gives no fixture or test-condition details.Agree reference leaks or artefacts, challenge tests and recorded limits.
CLEAR UP THE DETAIL

Equipment questions

Does the tester use helium detection?

The catalogue lists helium charging and airtightness detection as two separate stations. Ask Shuangren which detection method this machine uses.

Source s2
Can I compare its leak threshold with other testers?

The page gives no threshold. Get the method, units, test conditions and threshold together before comparing equipment on that full set.

Source s2
FROM READING TO A BRIEF

Prepare the supplier conversation

Fill in the conditions below and ask the supplier to answer each open point in writing. Copying or downloading stays in your browser; nothing is sent.

Prepare a full project brief →

SOURCES

Sources and check dates

The maker's own pages and public records used for this page, each with the date it was checked.

s1 · Company and supply-scope record

SHUANGREN · Manufacturer-origin source

Shuangren's company details and automation business.

Archived source check: 2026-10-07

s2 · Cell airtightness detection machine

SHUANGREN · Manufacturer-origin source

Catalogue listing for the airtightness detection machine within the finishing range.

Archived source check: 2026-10-07

s3 · Official portfolio context

SHUANGREN · Manufacturer-origin source

The neighbouring stations in Shuangren's range, such as helium charging and ball sealing.

Archived source check: 2026-10-07

Still to confirm

  • The detection method, helium mass spectrometry or another principle.
  • The test pressure, the units used for leak rate and the minimum detectable leak on your cell.
  • How fixture leakage is separated from a cell leak, and the reference-leak calibration.
  • Cycle time per cell and how retests and failed cells are logged.
BEFORE YOU REQUEST A QUOTE

Leak testing of sealed prismatic cells in the finishing line

  1. Test medium and detection principle
  2. Pressure, duration and reject threshold
  3. Part fixture and reference artefact
  4. Calibration and repeatability acceptance
Edit your enquiryRead the manufacturer dossier →
Analytics preferences

Usage analytics loads only with your consent. Private pages are excluded. Inquiry text and contact details are not sent to analytics.

Analytics has not been allowed.