Battery Manufacturing Equipment
EQUIPMENT • MIXING & MATERIAL PREPARATION

Kejing dual-planetary laboratory/pilot vacuum-mixing family

Kejing builds two dual-planetary vacuum mixers for electrode slurry: the MSK-SFM-18 for the lab, with a 2 L working fill, and the MSK-SFM-9-20L-2 for pilot batches, with a 20 L fill. Both combine planetary mixing, high-speed dispersion and vacuum, but their shafts and discs differ. They suit labs moving a slurry recipe from bench to pilot scale.

By Shenzhen Kejing Star Technology Company · MSK-SFM-9-20L-2 / MSK-SFM-18

BatteryEquip editorial teamSource review: 2026-10-11Buying guide based on the maker's published data.
PUBLISHED REFERENCE

Two sizes with different mixing hardware

The SFM-18 has a 2.9 L vessel, a 2 L maximum working volume and a listed minimum batch of 350 mL. It uses two twist-frame paddles, one dispersing disc and a scraper, with top speeds of 47 rpm revolution, 295 rpm mixing and 4000 rpm dispersion. The water-jacketed vessel can take optional cold or hot water.

The 20 L machine has a 25 L vessel and a 20 L working fill. It carries two mixing shafts, two dispersion shafts with four discs between them, and a removable PTFE wall scraper. It draws about 8 kW on three-phase 380 V and uses a 2XZ-2 pump; its −0.098 MPa vacuum figure applies to an empty vessel. The catalogue gives two different sets of dimensions for this machine, so ask for the current general arrangement drawing before planning the room.

Original parameter values · 3 entries
ParameterPublished valueRecord status
SFM-18 effective fill maximum2 Lknown
SFM-9-20L-2 effective fill20 Lknown
Pilot stated unloaded vacuum−0.098 MPaknown

Catalogue values apply to the configuration and test method the maker states. Ask for the values that apply to your configuration.

Source references: s1 s3

BUYER NOTES

Scale the slurry result along with the speeds

Specify the solvent and binder, powder loading, particle properties, how viscosity is measured, the order of addition and your targets for dispersion and air removal. Disc and paddle shapes and the working fill differ between the two machines, so the same rpm gives different shear. Match the slurry properties at pilot scale and adjust speeds to reach them.

The pilot catalogue gives an application range of 1000–100000 cP with loose viscosity wording. Ask Kejing for the measurement method, temperature and the speed or torque it refers to. Temperature is read at the vessel wall, so the bulk of the batch may differ from the jacket setting. Ask for vacuum performance with a loaded vessel, the temperature history of a batch and the sampling method used to judge mixing consistency.

Source references: s1 s3

BUYER NOTES

A past university purchase and your own trial

A public purchase record from ECUST dated 6 May 2025 shows one MSK-SFM-9-20L-2 mixer bought from Shenzhen Kejing. It confirms the model has been supplied; price and requirements in that record were for that buyer, so get a current signed specification and quotation for yours.

Watch batches at your minimum and working fill, keep the recipe and samples, and agree limits for residual material and cleaning between products. The pilot catalogue says the scraper comes out for high-viscosity work, so note which setup the trial used. Go through the lift, lid, vacuum, overcurrent and overtemperature protections using the supplier's procedures. Settle cooling, pump and cleaning responsibilities, spare seals and the finish of wetted parts before handover.

Kejing's profile lists the smaller MSK-SFM-16 for millilitre batches, the Kejing millilitre-scale mixer, and its lab coaters for the next step. Judge the slurry on a coated sample, as the coating width page explains, and agree the trial as the acceptance testing page suggests.

Source references: s1 s4

MAKE A SELECTION

Questions that change the purchase

DecisionWhat the catalogue saysNext step
Which working fill do you need?The vessels are 2.9 L and 25 L in total, with working fills of 2 L and 20 L.Trial your batch size in the chosen shaft arrangement.
What vacuum does the loaded slurry see?The catalogue gives −0.098 MPa for an empty pilot vessel.Agree a loaded vacuum hold and air-removal check.
Which installation drawing is current?The catalogue gives two different sets of pilot dimensions.Get a signed layout and utility schedule.
FROM READING TO A BRIEF

Prepare the supplier conversation

Fill in the conditions below and ask the supplier to answer each open point in writing. Copying or downloading stays in your browser; nothing is sent.

Prepare a full project brief →

SOURCES

Sources and check dates

The maker's own pages and public records used for this page, each with the date it was checked.

s1 · Kejing dual-planetary laboratory/pilot vacuum-mixing family original equipment description

Shenzhen Kejing · Manufacturer-origin source

Kejing's description of the dual-planetary mixer family, with vessel sizes, shafts, speeds, vacuum and services.

Archived source check: 2026-10-11

s2 · Official equipment catalogue with model links

Shenzhen Kejing · Manufacturer-origin source

Kejing's catalogue with links to each mixer model, useful for comparing the lab and pilot sizes.

Archived source check: 2026-10-11

s3 · Related laboratory planetary configuration

Shenzhen Kejing · Manufacturer-origin source

Kejing's page for the 2 L lab planetary mixer, with its paddles, disc, speeds and jacket options.

Archived source check: 2026-10-11

s4 · ECUST 2025 MSK-SFM-9-20L-2 purchase result

Original university public record · Public original record

A university purchase result showing one MSK-SFM-9-20L-2 mixer supplied by Shenzhen Kejing in 2025.

Archived source check: 2026-10-11

Read original record →

Still to confirm

  • Vacuum level with your slurry in the vessel.
  • The viscosity measurement behind the 1000–100000 cP range.
  • The current installation drawing for the 20 L machine.
  • Mixing consistency and batch temperature on your recipe at both scales.
BEFORE YOU REQUEST A QUOTE

Lab and pilot vacuum slurry mixing, 2 L to 20 L

  1. Formulation, working fill and viscosity method
  2. Chosen mixer and shaft setup, timed recipe
  3. Dispersion and air-removal sampling and limits
  4. Wall and bulk temperature, cooling, loaded vacuum trial
  5. Current dimensions, power and pump services
  6. Scraper use, cleaning, seals and interlock check
Edit your enquiryRead the manufacturer dossier →
Analytics preferences

Usage analytics loads only with your consent. Private pages are excluded. Inquiry text and contact details are not sent to analytics.

Analytics has not been allowed.