Battery Manufacturing Equipment
EQUIPMENT • FORMATION & TESTING

Hangke storage-cell high-temperature series negative-pressure formation machine

Hangke's storage-cell formation machine runs precharge and negative-pressure formation for prismatic storage cells at high temperature, with the cells charged in series. It combines power, mechanical, vacuum, safety and measurement and control modules. Hangke lists efficiency as CC≤85% and DC≤82% and claims better cell consistency and faster commissioning.

By Zhejiang Hangke Technology Incorporated Company

BatteryEquip editorial teamSource review: 2026-10-11Buying guide based on the maker's published data.
PUBLISHED REFERENCE

Series charging and the efficiency figures

The machine combines high-temperature operation, negative pressure and series charging, and Hangke says this improves cell consistency and commissioning speed. It gives no string length, per-cell voltage control, balancing method or temperature range. Ask for the circuit layout and what happens when one cell hits its voltage or temperature limit before the others, since cells sharing one current path can still behave differently.

The efficiency field reads CC≤85%, DC≤82%. Ask Hangke what CC and DC stand for and why the figures are written as upper limits, and get the definitions in writing. If you compare this machine with a water-cooled capacity-grading machine, use the same operating conditions and energy-metering points for both.

Original parameter values · 1 entries
ParameterPublished valueRecord status
Published efficiency statement, meanings to confirmCC≤85%; DC≤82% known

Catalogue values apply to the configuration and test method the maker states. Ask for the values that apply to your configuration.

Source references: s1

BUYER NOTES

Temperature and negative pressure in the real recipe

Send the storage-cell capacity, construction, fill-port details and the formation and rest sequence. Ask for the heating layout, allowed temperature spread and measuring points at the offered loading. The product name says high temperature but gives no range. For negative pressure, ask for the pressure reference, measuring point and leak and containment procedure that apply to this model.

In a series layout, define how contacts, wiring and vacuum hoses are checked and how a faulty position is isolated. Ask whether pulling one cell stops the whole string, how the remaining cells are held and how the recipe resumes. Include fixture cleaning and exhaust handling in the utility and maintenance scope, since cells can release gas or electrolyte during formation.

Source references: s1 s2

BUYER NOTES

Energy metering, cell records and fault handling

If energy efficiency matters to your purchase, agree where energy is metered, which charge/discharge conditions apply and whether pumps, heating, cooling and standby are counted. Get the manufacturer's explanation of the published CC/DC figures first. Build any payback estimate on your own metered acceptance run.

Record the voltage and temperature of each cell through a representative string, along with total current and pressure. Set allowed recipe deviations, reject handling and the link to later grading and inspection. Hangke names safety and measurement modules without a protection list. At handover, get the response to lost contact, overvoltage, abnormal temperature and power failure, with traceable recovery for part-processed cells.

Series formation trades individual channel control for lower conversion losses, so compare it with the Repower series formation system on cell isolation and fault handling.

Source references: s1

MAKE A SELECTION

Questions that change the purchase

DecisionWhat the catalogue saysNext step
How are cells controlled in the series circuit?The page gives no string length, balancing or per-cell limits.Review the circuit layout and watch a limiting-cell and fault sequence.
What do the efficiency figures mean?The page lists CC≤85% andDC≤82% without defining CC or DC.Get a written explanation and agree the energy-metering points.
Can thermal/vacuum conditions be qualified together?The page gives no temperature or pressure range or measuring method.Run the offered fixture with loaded cells and traceable sensors.
FROM READING TO A BRIEF

Prepare the supplier conversation

Fill in the conditions below and ask the supplier to answer each open point in writing. Copying or downloading stays in your browser; nothing is sent.

Prepare a full project brief →

SOURCES

Sources and check dates

The maker's own pages and public records used for this page, each with the date it was checked.

s1 · Hangke storage-cell high-temperature series negative-pressure formation machine original public data

Hangke Technology · Manufacturer-origin source

Describes the series negative-pressure formation modules, efficiency figures and consistency claims.

Archived source check: 2026-10-11

s2 · Hangke original post-processing equipment portfolio

Hangke Technology · Manufacturer-origin source

Shows the machine among Hangke's storage-cell formation and grading equipment.

Archived source check: 2026-10-11

Still to confirm

  • What CC and DC mean, and why the efficiency figures are written as upper limits.
  • String length, balancing method and per-cell limits.
  • The temperature range and the negative-pressure level and measuring point.
  • Good-cell output for your recipe.
BEFORE YOU REQUEST A QUOTE

High-temperature series formation of prismatic storage cells under negative pressure

  1. Cell capacity, fill port and formation and rest recipe
  2. String length, balancing, per-cell measurement and bypass
  3. Temperature range, loaded mapping and sensor positions
  4. Vacuum reference, sealing, exhaust and cleaning scope
  5. CC/DC definitions and energy-metering boundary
  6. Fault list, part-finished string recovery and cell records
Edit your enquiryRead the manufacturer dossier →
Analytics preferences

Usage analytics loads only with your consent. Private pages are excluded. Inquiry text and contact details are not sent to analytics.