Where the sorting data comes from

The page gives no cell format or size, grade count, handling mechanism or built-in capacity or voltage meter. Ask whether the results come from an earlier station or whether measurement is part of the quoted machine, and fix that boundary in the order. Ask also for this sorter's own handling limits; the force and temperature ranges on Hangke's all-solid-state formation equipment belong to that equipment.

Send the cell geometry, allowed contact and handling conditions and your grade rules. Define the required results, units, maximum age and recipe version, and what happens with missing or conflicting values. Ask how many grade positions the machine has, how much each holds and its sorting error rate.

Original parameter values · 1 entries
ParameterPublished valueRecord status
Published sorting-rate lower bound≥6 ppmknown

Catalogue values apply to the configuration and test method the maker states. Ask for the values that apply to your configuration.

Source references: s1

BUYER NOTES

Confirming each cell reaches its grade

Specify how cells are identified on entry and the layout of the receiving positions. Require a rule for full or unavailable grade positions and for results that fit no allowed grade. The proposal should show how the source position and the destination confirmation stay linked.

Run realistic grade mixes, a missing-result case and an uneven distribution using the supplier's safe sample set. Check handling condition and match the cells in each destination against their recorded grades. If output matters, count good sorted cells with blocked destinations and rejects included, since the ≥6 ppm figure comes without conditions.

Source references: s1 s2

BUYER NOTES

Cell entry state and recovery after a stop

For cells coming from a pressure- and temperature-controlled process, define the state in which the sorter takes them, and who handles load release or cool-down before that. Hangke does not say the sorter holds any compression or temperature while sorting, so agree these interfaces for your cell and upstream equipment.

Agree how a stop records cells already picked or part-moved, and check that a restart keeps every cell's identity. At handover, cover fixture and tool changes, wear checks, safe access and stored grade-rule versions. The sorter acts on your test data, so the quality of each grade depends on the upstream tests.

The capacity and voltage data come from formation and grading, as the formation and capacity grading page explains, and the cell measurement page describes the OCV and resistance values used. The acceptance testing page shows how to verify that sorted bins match the data.

Source references: s1

MAKE A SELECTION

Questions that change the purchase

DecisionWhat the catalogue saysNext step
Where do capacity/voltage results originate?The page describes sorting by results and names no meters.Define who owns upstream results and which fields are required.
What happens when a grade destination is full?The page lists multiple grades without receiving capacity.Watch blocked destinations and safe holds of the result.
What condition does the cell enter in?The page gives no load or temperature range.Agree upstream release, cool-down and handling limits.
FROM READING TO A BRIEF

Prepare the supplier conversation

Fill in the conditions below and ask the supplier to answer each open point in writing. Copying or downloading stays in your browser; nothing is sent.

Prepare a full project brief →

SOURCES

Sources and check dates

The maker's own pages and public records used for this page, each with the date it was checked.

s1 · Hangke solid-state result-based cell sorter original public data

Hangke Technology · Manufacturer-origin source

Describes result-based sorting, automatic loading and unloading, multiple grades and the ≥6 ppm rate.

Archived source check: 2026-10-11

s2 · Hangke original post-processing equipment portfolio

Hangke Technology · Manufacturer-origin source

Shows the sorter after Hangke's solid-state formation and grading equipment.

Archived source check: 2026-10-11

Still to confirm

  • The cell sizes, grade count and handling method.
  • Whether any measurement is included or all results come from upstream stations.
  • What the ≥6 ppm rate includes.
  • The entry condition required after pressure and temperature formation.
BEFORE YOU REQUEST A QUOTE

Sorting solid-state cells into grades from upstream test results

  1. Cell geometry and allowed mechanical and thermal entry state
  2. Result source, units, age and grade-rule version
  3. Grade count, destination layout and confirmations
  4. Incomplete or conflicting results and uneven-grade trial
  5. ≥6 ppm good-output counting conditions
  6. Interrupted-pick recovery, tooling and safe access
Edit your enquiryRead the manufacturer dossier →
Analytics preferences

Usage analytics loads only with your consent. Private pages are excluded. Inquiry text and contact details are not sent to analytics.

Analytics has not been allowed.