Battery Manufacturing Equipment
EQUIPMENT • FORMATION & TESTING

Hangke water-cooled prismatic/blade capacity-grading family

Hangke builds water-cooled, high-voltage DC-bus capacity-grading equipment in three versions: prismatic power cells with 200/400/800 A output, aluminium-case storage cells with ≤3°C temperature deviation, and vertical blade cells with PID control, ≤±2°C uniformity and 15–25% lower energy use. All grade cells by measured capacity after formation.

By Zhejiang Hangke Technology Incorporated Company

BatteryEquip editorial teamSource review: 2026-10-11Buying guide based on the maker's published data.
PUBLISHED REFERENCE

What each version lists

The prismatic power-cell version offers output current of 200/400/800 A and supports several tray types. It gives no current concurrency, voltage range or tray and contact drawings. The vertical blade version lists PID temperature control, ≤±2°C uniformity, 15–25% lower energy use and 52 protection items, without the energy baseline, measuring positions or a list of the protections.

The storage-cell version gives a temperature deviation of ≤3°C with water cooling, better efficiency and safety monitoring. That figure is a deviation, separate from the blade version's uniformity and from cell-temperature accuracy. Each figure belongs to its own version, so ask for the current options and energy figures of the storage version directly. Request a signed configuration with bus layout, per-channel limits and the installed contacts.

Original parameter values · 3 entries
ParameterPublished valueRecord status
Power-cell output-current configurations200 / 400 / 800 Aknown
Blade stated temperature uniformity≤±2 °Cknown
Storage stated temperature deviation≤3 °Cknown

Catalogue values apply to the configuration and test method the maker states. Ask for the values that apply to your configuration.

Source references: s1 s3 s4

BUYER NOTES

Fixing the capacity recipe

Send the cell's nominal and maximum voltage, the charge/discharge current, cut-offs, rest times and temperature conditions. Agree how capacity is integrated, its uncertainty and which result sets the grade. Hangke describes screening without a full capacity recipe, accuracy figure or grade limit, so put these in the order.

Run the chosen electrical sequence on representative cells with traceable meter checks. Check the contacts, the channel-to-cell map and shared bus and power limits at the planned simultaneous load. The current option tells you the channel rating; recipe length, loading, cooling and retest rules set the real output of the installed system.

Source references: s1 s3 s4

BUYER NOTES

Water cooling, protections and records

Specify coolant flow, supply temperature and quality, heat rejection and where temperature is judged. Decide whether the limit applies to air, coolant, fixture or cell temperature, and compare at the planned occupancy and load. Hangke gives no utility schedule or temperature map under load, so request both.

Ask for the list of protections and how each responds; the figure of 52 is a count. Define per-cell records of recipe, calibration and result, who owns the grade, recovery after an interruption and the handling of incomplete results. At handover, cover probe and tray maintenance, cooling isolation and changeover between configurations. Measure capacity, energy use and cell yield on your own cells during acceptance.

Upstream formation systems appear on Hangke's profile, and the formation and capacity grading page explains why grading needs a full cycle per cell.

Source references: s1 s3 s4

MAKE A SELECTION

Questions that change the purchase

DecisionWhat the catalogue saysNext step
Which configuration supplies the quoted current and temperature figures?Each of the three versions lists different current and temperature figures.Keep a signed specification for the version you buy.
What recipe defines the capacity grade?The pages list no cut-offs, duration or measurement uncertainty.Fix electrical and temperature conditions and who owns the grade.
Does cooling meet the limit under load?The temperature figures come without occupancy or measuring positions.Map agreed temperatures at the planned simultaneous load.
FROM READING TO A BRIEF

Prepare the supplier conversation

Fill in the conditions below and ask the supplier to answer each open point in writing. Copying or downloading stays in your browser; nothing is sent.

Prepare a full project brief →

SOURCES

Sources and check dates

The maker's own pages and public records used for this page, each with the date it was checked.

s1 · Hangke water-cooled prismatic/blade capacity-grading family original public data

Hangke Technology · Manufacturer-origin source

Describes the prismatic power-cell version with 200/400/800 A options and several tray types.

Archived source check: 2026-10-11

s2 · Hangke original post-processing equipment portfolio

Hangke Technology · Manufacturer-origin source

Shows the grading equipment within Hangke's formation and grading range.

Archived source check: 2026-10-11

s3 · Hangke water-cooled prismatic/blade capacity-grading family original public data

Hangke Technology · Manufacturer-origin source

Describes the vertical blade version with PID control, uniformity, energy and protection figures.

Archived source check: 2026-10-11

s4 · Hangke water-cooled prismatic/blade capacity-grading family original public data

Hangke Technology · Manufacturer-origin source

Describes the storage-cell version with water cooling and its temperature deviation figure.

Archived source check: 2026-10-11

Still to confirm

  • Capacity measurement uncertainty and the number of channels running at once.
  • Coolant flow, heat rejection and other utility needs for the delivered version.
  • The baseline and load behind the 15–25% energy and temperature figures.
  • The list of the 52 protection items.
BEFORE YOU REQUEST A QUOTE

Water-cooled capacity grading for prismatic, storage and blade cells

  1. Prismatic or blade geometry and tray and contact layout
  2. Voltage and current, channel concurrency and DC-bus layout
  3. Capacity recipe, cut-offs, rest and uncertainty
  4. Cooling services, sensor positions and loaded trial
  5. Per-cell result, grade rules and interrupted-cycle recovery
  6. Protection functions, calibration and contact maintenance
Edit your enquiryRead the manufacturer dossier →
Analytics preferences

Usage analytics loads only with your consent. Private pages are excluded. Inquiry text and contact details are not sent to analytics.

Analytics has not been allowed.