Battery Manufacturing Equipment
EQUIPMENT • FORMATION & TESTING

Hangke consumer-cell hot-press formation/grading family

Hangke makes two hot-press formation and grading machines for small consumer cells. The 3C version handles pouch cells for digital devices with precision pressure control at 16 ppm. The Bluetooth version adds robot handling, visual positioning, multi-model production, automatic changeover and defect screening at 15 ppm. Both combine formation and capacity grading.

By Zhejiang Hangke Technology Incorporated Company

BatteryEquip editorial teamSource review: 2026-10-11Buying guide based on the maker's published data.
PUBLISHED REFERENCE

The 3C and Bluetooth versions

Hangke describes the 3C version for pouch cells in digital devices. It combines formation and capacity grading with a modular, flexible layout and precision pressure control, and lists 16 ppm. It gives no force or pressure range, temperature range or measuring conditions. The Bluetooth version lists 15 ppm, robot logistics, visual positioning, multi-model production, and automatic changeover and defect screening. Those handling features belong to the Bluetooth version.

Ask what the rate counts: loading and unloading, fixture entry, or cells finishing a set electrical sequence. Formation includes charge, discharge and rest steps that take longer than a short mechanical cycle. Ask Hangke for current, capacity and temperature limits and the Bluetooth cell sizes it supports, since the application names give none.

Original parameter values · 2 entries
ParameterPublished valueRecord status
3C stated rate16 ppmknown
Bluetooth stated rate15 ppmknown

Catalogue values apply to the configuration and test method the maker states. Ask for the values that apply to your configuration.

Source references: s1 s3

BUYER NOTES

Fixtures, contacts and the electrical recipe

Send the case or pouch size, tab positions, thickness tolerance and how much compression or deformation is allowed. Agree the contact surfaces, load spread and terminal sensing. Hangke mentions precision pressure without a contact area or accuracy figure, so request a force or pressure definition and calibration method for your configuration.

Specify the electrical steps, cut-offs, rest times and where temperature is measured. Run representative cells and record the fixture and recipe version with each result. For changeover, check how tools are identified and what stops a new cell size from running on the old recipe or vision position. Ask Hangke which consumer-cell drawings it has already run on the machine.

Source references: s1 s3

BUYER NOTES

Defect screening, fault recovery and handover

For the Bluetooth version, ask for the list of defect checks and the physical hold and reject route. Visual positioning locates the cell; ask whether it also inspects anything. For both machines, agree the steps for cutting electrical power, controlling heat and load, and releasing a cell after an interruption.

At handover, cover fixture and contact wear, calibration of electrical, load and temperature readings, guards, robot access where fitted, and who owns recovery. If the catalogue rate drives your purchase, count good cells over the full agreed recipe. Ask Hangke to state force range, cell yield and defect detection rate in the offer, because the summaries give no figures for them.

Hangke's profile lists its larger formation systems, and the acceptance test planning page sets out how to check temperature and pressure on a full fixture.

Source references: s1 s3

MAKE A SELECTION

Questions that change the purchase

DecisionWhat the catalogue saysNext step
What operation does 16/15 ppm count?The catalogue gives 16 and 15 ppm without recipe or channel details.Count good output over the full chosen sequence.
Can the fixture accept the new cell tabs?The catalogue gives no cell size or contact range.Approve your drawing and run a loaded trial.
Which defects are actually screened?The Bluetooth version names defect screening without methods.List the tests, limits and reject route in the offer.
FROM READING TO A BRIEF

Prepare the supplier conversation

Fill in the conditions below and ask the supplier to answer each open point in writing. Copying or downloading stays in your browser; nothing is sent.

Prepare a full project brief →

SOURCES

Sources and check dates

The maker's own pages and public records used for this page, each with the date it was checked.

s1 · Hangke consumer-cell hot-press formation/grading family original public data

Hangke Technology · Manufacturer-origin source

Describes the 3C pouch-cell hot-press formation and grading version and its 16 ppm rate.

Archived source check: 2026-10-11

s2 · Hangke original post-processing equipment portfolio

Hangke Technology · Manufacturer-origin source

Shows the consumer-cell machines within Hangke's formation and grading range.

Archived source check: 2026-10-11

s3 · Hangke consumer-cell hot-press formation/grading family original public data

Hangke Technology · Manufacturer-origin source

Describes the Bluetooth-cell version with robot handling, changeover, screening and a 15 ppm rate.

Archived source check: 2026-10-11

Still to confirm

  • Force and temperature ranges and electrical ratings for each version.
  • The consumer cell sizes and tab layouts each fixture accepts.
  • What the 16 and 15 ppm rates count, and with which recipe.
  • Which defects the Bluetooth version screens, and by what method.
BEFORE YOU REQUEST A QUOTE

Hot-press formation and grading of small consumer pouch cells

  1. Consumer cell and tab drawing and chosen version
  2. Force or pressure definition, contact area and deformation limit
  3. Electrical recipe, temperature points and calibration
  4. Rate counting basis and installed channel layout
  5. Vision and changeover checks and screening scope
  6. Hot-fixture isolation, reject handling and wear maintenance
Edit your enquiryRead the manufacturer dossier →