Gelon pouch electrolyte filling and vacuum-sealing system

Gelon's automatic pouch filling system scans each cell's barcode, weighs it, fills electrolyte, lets it stand, vacuum-seals it and weighs it again before unloading. The two weighings give a per-cell record of electrolyte added. It suits pouch lines that want filling, sealing and a mass check in one sequence, with dose and hold settings agreed per cell design.

By Gelon Lib Group Co., Ltd.

BatteryEquip editorial teamSource review: 2026-10-11Buying guide based on the maker's published data.
PUBLISHED REFERENCE

Two weighings around the fill

Gelon lists barcode scanning, pre-fill weighing, automatic electrolyte filling, automatic standing, automatic vacuum sealing, post-fill weighing and unloading. Dose range, pump type, scale resolution, dosing accuracy, vacuum level, standing time, pouch sizes and cycle rate are not given, so ask for them before any comparison with other offers.

Specify the pouch opening, tab orientation, gas pocket allowance and cell mass range. Ask the supplier which unit does each step and which values are recorded. Agree the record format, how each value is tied to one cell, what happens when a barcode cannot be read, and whether any database or MES link is included.

Original parameter values · 2 entries
ParameterPublished valueRecord status
Listed mass checksBefore and after electrolyte filling known
Documented operation after standingAutomatic vacuum sealing known

Catalogue values apply to the configuration and test method the maker states. Ask for the values that apply to your configuration.

Source references: s1

BUYER NOTES

Using the mass difference

The gain between the two weighings can check the dose by mass, as long as scale performance, handling losses and reference conditions are under control. Ask for scale range, resolution, calibration method and settling conditions at both stations. If the filler meters volume, agree the density and temperature used to compare it with the measured mass.

Ask how drips, outside contamination, evaporation and material lost during sealing are treated in the pass or fail decision. The mass gain shows how much electrolyte went in; whether it reached every part of the electrode stack is a separate wetting question. Have Gelon show both dose and wetting with your electrolyte and real cells.

Source references: s1

BUYER NOTES

Standing time and vacuum seal

The standing step has no listed time, temperature or pressure. Give Gelon your hold requirement and ask how many positions that needs and what it does to sustained output. If you need soaking under pressure cycles, ask for it by name, since the page describes plain standing.

For the vacuum seal, set the pressure reference, seal position, tooling and integrity check, plus electrolyte compatibility and cleaning access. Moisture control, exhaust and the operating environment belong in the installation proposal. During acceptance, interrupt a fill and trigger a mass reject to check safe recovery, part identity and separation of unfinished cells.

Cells should be dried before filling, as the electrode drying page explains.

Source references: s1

MAKE A SELECTION

Questions that change the purchase

DecisionWhat the catalogue saysNext step
Is the dosing decision mass-based or volume-based?The page lists weighing before and after filling with no dosing method or tolerance.Agree the measurement chain, density basis and calibration.
Does the standing stage support the cell recipe?The page gives no hold time or conditions.Set the hold you need and show its effect on positions and output.
Can a mass gain establish wetting?The page shows no wetting results.Set a separate wetting test alongside dose and seal acceptance.
FROM READING TO A BRIEF

Prepare the supplier conversation

Fill in the conditions below and ask the supplier to answer each open point in writing. Copying or downloading stays in your browser; nothing is sent.

Prepare a full project brief →

SOURCES

Sources and check dates

The maker's own pages and public records used for this page, each with the date it was checked.

s1 · Gelon pouch electrolyte filling and vacuum-sealing system — manufacturer equipment page

Gelon · Manufacturer-origin source

Gelon's product page listing the barcode, weighing, filling, standing, vacuum sealing and unloading steps.

Archived source check: 2026-10-11

s2 · Gelon official equipment portfolio

Gelon · Manufacturer-origin source

Gelon's equipment range, including four-station fillers and post-formation degassing machines.

Archived source check: 2026-10-11

Still to confirm

  • Dose range, dosing accuracy and the scale resolution at both weighing stations.
  • Standing time and conditions, and the number of standing positions.
  • Vacuum level for sealing and the supported pouch sizes.
  • Cycle rate and whether records link to your MES.
BEFORE YOU REQUEST A QUOTE

Pouch electrolyte filling with before-and-after weighing

  1. Pouch opening, gas pocket, tab orientation and cell mass
  2. Electrolyte compatibility, dose range and mass tolerance
  3. Pre/post scales, calibration and density/temperature basis
  4. Standing time, pressure and occupied-position requirement
  5. Vacuum sealing geometry and integrity inspection
  6. Cell-linked records, interrupted fill and reject recovery
Edit your enquiryRead the manufacturer dossier →
Analytics preferences

Usage analytics loads only with your consent. Private pages are excluded. Inquiry text and contact details are not sent to analytics.

Analytics has not been allowed.