Gelon GN-VM-7P three-stage vacuum slurry mixer
The Gelon GN-VM-7P is a small vacuum mixer for electrode slurry with PLC touchscreen control, forward and reverse rotation, three programmable speed stages up to 1000 rpm and a built-in vacuum generator. Vessels range from 50 to 500 ml, with one size supplied as standard. At about 40 kg it suits laboratory batches on a bench or in a glovebox.
By Gelon Lib Group Co., Ltd. · GN-VM-7P
Vessel sizes and working fills
Gelon offers nominal tanks of 50, 150, 250, 300 and 500 ml, and one of them comes as standard. The 50 ml tank holds up to 30 ml with a single paddle, the 150 ml tank 120 ml with double paddles, and the 500 ml tank 400 ml with double paddles. For the 250 and 300 ml tanks, ask Gelon for the working fill and paddle type.
You can program three speed stages, up to 1000 rpm, with mixing time from 0 to 600 minutes. Rotation runs forward and reverse, and a vacuum system is built in. The vacuum line reads equal to or greater than −70 kPa. Ask Gelon to state the gauge reference and the vacuum level actually reached with a loaded vessel.
| Parameter | Published value | Record status |
|---|---|---|
| Maximum listed mixing speed | 1000 rpm | known |
| Programmable speed stages | 3 | known |
| Nominal/effective examples | 50/30; 150/120; 500/400 ml | known |
| Adjustable mixing time | 0–600 min | known |
| Listed power | 500 W | known |
Catalogue values apply to the configuration and test method the maker states. Ask for the values that apply to your configuration.
Source references: s1
Build the stage recipe around your slurry
Send your formulation, solids, addition order and a viscosity figure with its measuring conditions. Agree speed, time and direction for each stage, with the usable fill, temperature and the measurements that accept a batch. Gelon describes the mixer as suited to high viscosity and bubble removal without a torque curve or temperature limit, so test your thickest slurry.
Ask for paddle geometry, wetted surfaces and seals for the vessel you choose. After the full recipe, check homogeneity and trapped gas using your own sampling method. Log the vacuum reading with its gauge reference during loaded mixing.
Source references: s1
Utilities and glovebox use
For glovebox work the mixer takes argon or nitrogen at 0.5–0.8 MPa, and outside a glovebox it takes compressed air. Electrical builds cover AC220 V/50 Hz and AC110 V/60 Hz. Power is 500 W, the unit measures about 350 ×330 ×590 mm and weighs about 40 kg. Confirm gas flow, vacuum exhaust and service access; the glovebox is a separate purchase.
Check that there is room to lift out the vessel and paddle as well as to fit the body. Include discharge, residue and cleaning in the mixing trial. At handover, check the delivered vessel, the stage controls, recovery from an interruption and the stored recipe. One family covers all five vessel sizes, so name your size in the order.
The coated sample shows whether the slurry is usable, as the coating width page explains, and the Gelon small-batch planetary mixer is the next size up for longer trials.
Source references: s1
Questions that change the purchase
| Decision | What the catalogue says | Next step |
|---|---|---|
| Which vessel and effective fill are delivered? | One vessel is standard, and working fills are listed for the 50, 150 and 500 ml sizes. | Specify the chosen container, paddle and fill for your material. |
| What does the vacuum inequality mean? | The page reads equal to or greater than −70 kPa. | Get the gauge definition and the measured loaded level. |
| Does the staged recipe meet the slurry endpoint? | The page lists 1000 rpm and three stages. | Qualify uniformity, temperature and trapped gas on your batch. |
Prepare the supplier conversation
Fill in the conditions below and ask the supplier to answer each open point in writing. Copying or downloading stays in your browser; nothing is sent.
Sources and check dates
The maker's own pages and public records used for this page, each with the date it was checked.
s1 · Gelon GN-VM-7P three-stage vacuum slurry mixer — manufacturer equipment page
Gelon · Manufacturer-origin source
Gelon's product page with vessel sizes and fills, speed stages, mixing time, vacuum entry, gas, power, size and mass.
Archived source check: 2026-10-11
s2 · Gelon official equipment portfolio
Gelon · Manufacturer-origin source
Gelon's equipment range, including larger planetary mixers for bigger batches.
Archived source check: 2026-10-11
Still to confirm
- Working fill and paddle type for the 250 ml and 300 ml vessels.
- The vacuum level reached with a loaded vessel and its gauge reference.
- Motor torque at high viscosity and any temperature limit for the slurry.
- Which vessel size is supplied as standard in your quote.
Laboratory vacuum mixing of small slurry batches
- Slurry formulation, solids, addition sequence and viscosity method
- Selected vessel/paddle and effective/minimum fill
- Three stages, direction, torque and temperature requirements
- Vacuum reference, loaded capability and exhaust
- Wetted materials, recovery and cleaning acceptance
- Glovebox gas flow, layout, selected voltage and recipe recovery