Gelon glovebox-use cylindrical electrolyte filling module

Gelon's modular injector fills 18650 and 21700 cylindrical cells with electrolyte and is built to work inside a glovebox. It measures 3600 ×1150 ×1000 mm and runs on 220 V/50 Hz at 4 kW. Gelon lists a qualification rate of at least 99.8% and utilisation of at least 96%. It suits small cylindrical cell lines.

By Gelon Lib Group Co., Ltd.

BatteryEquip editorial teamSource review: 2026-10-11Buying guide based on the maker's published data.
PUBLISHED REFERENCE

Injector and enclosure scope

Gelon describes a modular electrolyte injector for 18650 and 21700 cells that runs inside a glovebox. It measures 3600 ×1150 ×1000 mm and takes a 220 V/50 Hz input at 4 kW. Check those dimensions against your enclosure, its access openings and the room needed for service. Ask whether the glovebox, gas purifier and atmosphere monitor come with the injector or must be bought separately.

Dose range, metering method, pressure sequence, nozzle layout and the cell opening shapes it accepts are not listed. Send your electrolyte properties and cell drawing so Gelon can propose a filling setup. The fill recipe and wetting result then have to be proven on your cells.

Original parameter values · 4 entries
ParameterPublished valueRecord status
Named cell formats18650 / 21700 known
Listed intended environmentGlovebox use known
Listed input power4 kWknown
Listed dimensions3600 ×1150 ×1000 mmknown

Catalogue values apply to the configuration and test method the maker states. Ask for the values that apply to your configuration.

Source references: s1

BUYER NOTES

Get a clear rate figure

The table gives equipment efficiency as at least 30 PPM/min. If PPM already means pieces per minute, the extra per minute doubles the time unit, so ask Gelon for a corrected rate and how it is counted. Product qualification is listed at 99.8% or more in batch operation and utilisation at 96% or more, excluding human error. Neither figure comes with a run length or a definition of a reject.

Decide which downtime and manual steps count during acceptance. A utilisation figure that leaves out operator errors needs adjusting before any comparison with another supplier's availability. Run your own cells and electrolyte, record accepted fills, and note how setup, refilling and glovebox access cut into steady output.

Source references: s1

BUYER NOTES

A dose you can check and a layout you can service

State the electrolyte mass you need, the allowed variation and how you will measure it. Ask about calibration, temperature and density correction if the pump meters volume, nozzle drips and material compatibility. Plan separate checks for dose accuracy and electrode wetting, since a correct dose can still leave dry spots.

For the glovebox, request a layout showing feedthroughs, access, spill collection and service tasks against your atmosphere requirements. Interrupt a dose and reject a cell during the trial to see that recovery keeps track of each part. At handover, get the written recipe and maintenance method for the exact injector and enclosure you receive.

Gelon's profile lists the case grooving and cap welding machines used around this module, and the electrode drying page explains why the glovebox atmosphere matters.

Source references: s1

MAKE A SELECTION

Questions that change the purchase

DecisionWhat the catalogue saysNext step
Is the glovebox part of the quote?The page describes the injector for use in a glovebox and lists no enclosure package.Identify enclosure, atmosphere and maintenance interfaces.
What is the actual output unit?The table prints 30 PPM/min.Get a corrected accepted-fill rate and trial conditions.
How is the fill quantity accepted?The page lists no dose range, metering method or tolerance.Agree calibration and cell-specific dose measurement, and check wetting separately.
FROM READING TO A BRIEF

Prepare the supplier conversation

Fill in the conditions below and ask the supplier to answer each open point in writing. Copying or downloading stays in your browser; nothing is sent.

Prepare a full project brief →

SOURCES

Sources and check dates

The maker's own pages and public records used for this page, each with the date it was checked.

s1 · Gelon glovebox-use cylindrical electrolyte filling module — manufacturer equipment page

Gelon · Manufacturer-origin source

Gelon's product page naming the cell formats, glovebox use, dimensions, power, rate, qualification and utilisation figures.

Archived source check: 2026-10-11

s2 · Gelon official equipment portfolio

Gelon · Manufacturer-origin source

Gelon's equipment range, including grooving and cap welding machines for the same cylindrical formats.

Archived source check: 2026-10-11

Still to confirm

  • Whether the glovebox, purifier and atmosphere monitoring are included, and the moisture limit supported.
  • The dose range, metering method and dose tolerance.
  • The correct output rate in place of 30 PPM/min and how it is counted.
  • How the 99.8% qualification and 96% utilisation figures were measured.
BEFORE YOU REQUEST A QUOTE

Glovebox electrolyte filling for 18650 and 21700 cells

  1. Cell opening, 18650/21700 tooling and target electrolyte mass
  2. Electrolyte compatibility, dose tolerance and calibration
  3. Glovebox scope, atmosphere requirements and service layout
  4. Nozzle, pressure sequence, spills and interrupted-dose recovery
  5. Corrected throughput unit and utilisation inclusions
  6. Wetting qualification, accepted-fill records and handover
Edit your enquiryRead the manufacturer dossier →
Analytics preferences

Usage analytics loads only with your consent. Private pages are excluded. Inquiry text and contact details are not sent to analytics.

Analytics has not been allowed.