Battery Manufacturing Equipment
EQUIPMENT • CELL ASSEMBLY

Gelon desktop stepper-controlled cylindrical electrolyte filler

Gelon's desktop filler doses electrolyte into cylindrical cells through an injection pump with an internal stepper motor, set from a control console. It covers 18650, 21700, 26650 and 32650 formats with a 0–7.2 ml range and listed ±1% precision, in single or double head form. It suits laboratory and small-batch cell building.

By Gelon Lib Group Co., Ltd.

BatteryEquip editorial teamSource review: 2026-10-11Buying guide based on the maker's published data.
PUBLISHED REFERENCE

Console, stepper pump and head options

Gelon sells this as 18650 single or double head filling equipment, so choose the head count when you order. A console sets volume and speed, and the injection pump runs from a stepper motor. Listed formats are 18650, 21700, 26650 and 32650, the dose range is 0–7.2 ml, and one battery takes about one minute. Ask for the cell opening and tooling drawing for your format.

Precision is printed as ±1% with no statement of whether it refers to full scale or the set dose. Power is written as 220 V, which gives the voltage only. Air is listed at 75 PSI, and the customer supplies both vacuum and compressed air. Confirm the nozzle and pump setup, the electrical load and the vacuum level needed.

Original parameter values · 4 entries
ParameterPublished valueRecord status
Published dosing range0–7.2 mlknown
Stated precision; basis to confirm±1 %known
Source cycle reference; conditions unspecifiedAbout 1 minute per battery known
Listed air pressure75 PSIknown

Catalogue values apply to the configuration and test method the maker states. Ask for the values that apply to your configuration.

Source references: s1

BUYER NOTES

Check delivered dose against a scale

Send the electrolyte composition, its density at a stated temperature, its viscosity and your target quantity. Ask how a stepper setting turns into delivered volume and how calibration covers your working dose, beyond the ends of the range. Very small doses near the 0 ml end of the range need their own check.

Agree measurement uncertainty, the number of repeat samples and the density conversion if you weigh the dose. Watch for drips, leftover liquid and priming and refill behaviour on the actual pump and nozzle. Ask for the wetted materials and solvent compatibility, which are not listed. Accurate dosing is one step; electrode wetting depends on your cell and process.

Source references: s1

BUYER NOTES

Plan the whole fill, utilities included

A double head is its own configuration, and output may not double, so ask whether the two heads dispense together or in turn. Find out the operator steps and how the one-minute figure is counted. A fair trial includes placing the cell, completing the fill and taking it out.

Get the vacuum and air quality and flow, plus collection and cleaning arrangements, from the supplier documents. No vacuum pressure is given. Interrupt a dose, provoke an out-of-limit result and watch recovery after a refill. At handover, record the head, nozzle, calibration and utilities used for the accepted dose records. This is a desktop tool for manual filling work.

Cells must be dry before filling, which the electrode drying page explains, and the formation and capacity grading page covers the first charge after sealing.

Source references: s1

MAKE A SELECTION

Questions that change the purchase

DecisionWhat the catalogue saysNext step
What does ±1% describe?The page prints ±1% with no basis or calibration method.Agree dose-point measurement and repeatability with your electrolyte.
Which head configuration is delivered?The page offers single and double heads.Specify head count, nozzle and how the heads dispense.
What must the site supply?The page states that the customer provides vacuum and compressed air.Obtain vacuum, air and electrical-load requirements.
FROM READING TO A BRIEF

Prepare the supplier conversation

Fill in the conditions below and ask the supplier to answer each open point in writing. Copying or downloading stays in your browser; nothing is sent.

Prepare a full project brief →

SOURCES

Sources and check dates

The maker's own pages and public records used for this page, each with the date it was checked.

s1 · Gelon desktop stepper-controlled cylindrical electrolyte filler — manufacturer equipment page

Gelon · Manufacturer-origin source

Gelon's product page with the cell formats, dose range, precision, cycle time and utilities the buyer provides.

Archived source check: 2026-10-11

s2 · Gelon official equipment portfolio

Gelon · Manufacturer-origin source

Gelon's equipment range, including its glovebox filling modules and other cylindrical-cell tools.

Archived source check: 2026-10-11

Still to confirm

  • What the ±1% figure refers to, and the dose accuracy at your target volume.
  • The wetted materials and their compatibility with your electrolyte.
  • The vacuum level and air flow the site must provide, and the electrical load.
  • The cell tooling for your format and how the one-minute cycle is counted.
BEFORE YOU REQUEST A QUOTE

Laboratory electrolyte dosing for cylindrical cells

  1. Cell opening/tooling and selected single/double head
  2. Electrolyte compatibility, density/temperature and target dose
  3. Meaning of ±1%, calibration points and uncertainty
  4. Pump/nozzle priming, drips and refill behaviour
  5. Customer vacuum, 75 PSI air and actual flow/load
  6. Operator-inclusive cycle, wetting boundary and interrupted-dose recovery
Edit your enquiryRead the manufacturer dossier →
Analytics preferences

Usage analytics loads only with your consent. Private pages are excluded. Inquiry text and contact details are not sent to analytics.