ACEY-SF-1-500ML is a benchtop SUS304 filter that screens up to 500 ml of electrode slurry before lab coating. It ships with 80, 100 and 150 mesh screens, finer screens are optional, and a small vacuum generator pulls the slurry through. It suits removing oversized particles from sample batches.

By Xiamen Acey New Energy Technology Co., Ltd. · ACEY-SF-1-500ML

BatteryEquip editorial teamSource review: 2026-10-11Buying guide based on the maker's published data.
PUBLISHED REFERENCE

Match the screen to what should pass through

ACEY lists a 500 ml capacity, SUS304 construction and supplied screens of 80, 100 and 150 mesh. Finer optional screens are described as below 1000 mesh. Mesh numbers vary between standards, so ask for the screen standard, wire diameter, true aperture and the list of screens you will receive. The page also gives a 124 µm filtration figure without saying which screen it belongs to; ask ACEY to match it to a screen.

A screen holds back whatever cannot physically pass under the real flow conditions. Decide first what you want to catch. A harmful contaminant should be removed, while an active or conductive agglomerate is better broken up in the mixer. Measure both the filtrate and the solids caught on the screen, because losing part of your formulation can change how the electrode coats.

Original parameter values · 6 entries
ParameterPublished valueRecord status
Listed sample capacity500 mlknown
Supplied screen mesh counts80 / 100 / 150 meshknown
Listed air-pump flow3 L/minknown
Published absolute vacuum entry65 kPaknown
Filter dimensions145 × 150 × 200 mmknown
Listed mass4 kgknown

Catalogue values apply to the configuration and test method the maker states. Ask for the values that apply to your configuration.

Source references: s1

BUYER NOTES

Ask how iron is removed

ACEY's description says the device removes large particles and iron impurities. The specification gives no magnetic circuit, no capture strength and no iron-removal test. Ask the manufacturer to name the actual mechanism and show a trial on deliberately contaminated slurry. Iron particles smaller than the screen aperture pass through a plain screen.

If iron is a concern in your project, state the particle type, size and concentration, and agree an analysis method for samples taken before and after filtering. Keep three questions apart: what the screen catches, what a magnet catches if one is fitted, and what the filter's own wetted parts might shed into the slurry.

Source references: s1

BUYER NOTES

Time the filtration and weigh the recovered slurry

ACEY lists an absolute vacuum of 65 kPa, an air-pump flow of 3 L/min and a power adapter for AC 220 V ±10%/50 Hz. Ask where and in what state the pressure is measured, and whether the pump suits your solvent. Pump airflow is a different quantity from slurry throughput. How long a high-solids paste takes to pass depends on its viscosity, so measure it.

The filter measures 145 × 150 × 200 mm and the air generator 140 × 70 × 150 mm, with a listed weight of 4 kg. Check the seals, screen support, cleaning access and solvent handling. Acceptance should record recovered slurry, elapsed time, screen blockage, caught solids and a coating sample made afterwards. Ask for a cleaning procedure that keeps cathode or anode residue out of the next formulation.

Agglomerates caught here would otherwise show up as streaks on the coated sample; the coating width page explains how to inspect it.

Source references: s1

MAKE A SELECTION

Questions that change the purchase

DecisionWhat the catalogue saysNext step
What aperture is actually delivered?The page lists 80, 100 and 150 mesh screens and a 124 µm figure without linking them.Specify the screen standard and aperture and agree a retention test.
How is iron captured?The page says iron impurities are removed but describes no magnet.Get a written mechanism and before/after contamination measurements.
What slurry is recovered?The page gives a 500 ml capacity and 3 L/min pump flow but no slurry throughput.Measure recovery, caught solids, time and the coating that follows.
CLEAR UP THE DETAIL

Equipment questions

Can filtering replace adequate slurry mixing?

No. The device has no dispersion function. A screen can take out oversized material, but it leaves dispersion quality, formulation balance and dissolved impurities as they were. Fix agglomeration and contamination at the mixing stage, then use the filter as one sample-preparation step.

FROM READING TO A BRIEF

Prepare the supplier conversation

Fill in the conditions below and ask the supplier to answer each open point in writing. Copying or downloading stays in your browser; nothing is sent.

Prepare a full project brief →

SOURCES

Sources and check dates

The maker's own pages and public records used for this page, each with the date it was checked.

s1 · ACEY-SF-1-500ML laboratory electrode-slurry filter — manufacturer equipment page

ACEY · Manufacturer-origin source

ACEY's product page listing capacity, screen meshes, filtration figure, vacuum, pump flow, sizes and weight.

Archived source check: 2026-10-11

s2 · ACEY official equipment portfolio

ACEY · Manufacturer-origin source

ACEY's lab range, including the mixers that come before this filter and the coaters that follow.

Archived source check: 2026-10-11

Still to confirm

  • Which supplied screen gives the 124 µm figure, and the true aperture of each screen.
  • How the filter removes iron, with before-and-after results on contaminated slurry.
  • Filtration time and recovered volume at your slurry's solids and viscosity.
BEFORE YOU REQUEST A QUOTE

Small-volume screen filtration of electrode slurry with controlled retention and recovery

  1. Slurry solids, viscosity, solvent and batch size
  2. Screen standard, apertures and particles to be caught
  3. Iron-removal mechanism and test method
  4. Vacuum reference, seals and pump compatibility
  5. Recovery, blockage, cleaning and coating trial
Edit your enquiryRead the manufacturer dossier →
Analytics preferences

Usage analytics loads only with your consent. Private pages are excluded. Inquiry text and contact details are not sent to analytics.

Analytics has not been allowed.