Battery Manufacturing Equipment
EQUIPMENT • MIXING & MATERIAL PREPARATION

ACEY-PVM-250ML programmable vacuum slurry mixer

ACEY-PVM-250ML is a benchtop dual-shaft vacuum mixer for small electrode-slurry batches. It runs three programmed speed stages up to 600 rpm in forward or reverse, with a built-in vacuum pump and optional tanks from 150 to 500 ml. Lab teams use it to develop and repeat slurry recipes before scale-up.

By Xiamen Acey New Energy Technology Co., Ltd. · ACEY-PVM-250ML

BatteryEquip editorial teamSource review: 2026-10-11Buying guide based on the maker's published data.
PUBLISHED REFERENCE

Choose the tank and paddle as a pair

ACEY fits twin-shaft screw paddles as standard, offers single-shaft blade paddles as an option, and sells tanks from 150 to 500 ml. Pick the tank and paddle together, because a different volume changes clearance, wetting and how the slurry discharges. Ask for the delivered parts list and the minimum and maximum working fill for each tank. A tank's nominal size is larger than the batch it mixes well.

Top stirring speed is 600 rpm, with three speed stages and a timer from 0 to 600 minutes. Ask whether direction, vacuum and the change between stages can be programmed for each stage. Record the manual addition steps too. Three stored speed and time values repeat only part of a recipe, and the operator's sequence completes it.

Original parameter values · 6 entries
ParameterPublished valueRecord status
Accessory vessel volumes150–500 mlknown
Maximum listed stirring speed600 rpmknown
Programmable speed stages3 known
Mixing time-setting range0–600 minknown
Rated power200 Wknown
Approximate mass35 kgknown

Catalogue values apply to the configuration and test method the maker states. Ask for the values that apply to your configuration.

Source references: s1

BUYER NOTES

Check vacuum at the fill you will use

ACEY gives the built-in pump a −0.08 MPa vacuum figure and says it holds for two hours without an obvious drop. Ask for the gauge reference, where pressure is measured and how the hold is judged, and whether the hold is tested at rest or while mixing.

Vacuum helps remove trapped gas. ACEY gives no figure for the gas left in a finished slurry, so measure it on your own material. Check solvent compatibility, foam and carry-over into the pump line, and pump maintenance. Make a loaded-tank vacuum check part of acceptance, since viscosity, outgassing and material additions all change the result compared with an empty vessel.

Source references: s1

BUYER NOTES

Small batches: recovery and cleaning

ACEY lists AC 220 V, 200 W and about 35 kg. The first dimension is printed as '335m' next to 325 mm and 575 mm, so ask for a corrected dimension drawing. Check room for opening the lid, removing the tank and working inside a glovebox or dry room if you need one.

Send a representative formulation. Measure viscosity by an agreed method, look for agglomerates, record temperature rise and weigh the slurry you recover. In a small lab batch, the slurry left on paddles and walls can be a large share of the total. Ask to see the mixer taken apart and cleaned for your planned material changes, and check seals and scrapers for wear that could contaminate the slurry.

ACEY's profile lists the coaters and filters used after mixing, such as the ACEY slurry filter. The coating width page covers how to judge the coated sample. As the RFQ guide suggests, ask for programme and vacuum records in the quotation.

Source references: s1

MAKE A SELECTION

Questions that change the purchase

DecisionWhat the catalogue saysNext step
Which tank/paddle set is included?The page offers tanks from 150 to 500 ml and twin-screw or single-blade paddles.Confirm tank geometry, working fill and delivered parts.
How is the vacuum figure tested?The page gives −0.08 MPa and a two-hour hold without a gauge reference.Agree an empty-tank and a loaded vacuum check with solvent safeguards.
Can small batches be recovered consistently?The page gives no recovered-mass or cleaning figures.Weigh the recovered slurry and measure its properties after the full procedure.
CLEAR UP THE DETAIL

Equipment questions

Will the same programmed recipe work with another tank?

Often it will need changes. Fill level, tank shape and paddle clearance all affect mixing and heat transfer. When you switch tanks, re-run the same slurry measurements before you rely on the recipe. ACEY offers no single recipe for every tank size.

FROM READING TO A BRIEF

Prepare the supplier conversation

Fill in the conditions below and ask the supplier to answer each open point in writing. Copying or downloading stays in your browser; nothing is sent.

Prepare a full project brief →

SOURCES

Sources and check dates

The maker's own pages and public records used for this page, each with the date it was checked.

s1 · ACEY-PVM-250ML programmable vacuum slurry mixer — manufacturer equipment page

ACEY · Manufacturer-origin source

ACEY's product page giving tank options, paddle types, speed stages, vacuum figure, power and size.

Archived source check: 2026-10-11

s2 · ACEY official equipment portfolio

ACEY · Manufacturer-origin source

ACEY's lab range, including the slurry filters and coaters used after mixing.

Archived source check: 2026-10-11

Still to confirm

  • The correct value and unit of the first machine dimension, printed as '335m'.
  • The minimum and maximum working fill for each tank and paddle set.
  • The gauge reference and test conditions behind the −0.08 MPa two-hour vacuum hold.
  • Slurry results on your formulation, including recovered mass after cleaning.
BEFORE YOU REQUEST A QUOTE

Programmable small-batch vacuum slurry preparation with interchangeable vessels

  1. Tank and paddle configuration and working fill
  2. Formulation and manual addition sequence
  3. Stage controls and interruption recovery
  4. Pressure reference, carry-over and cleaning procedure
  5. Slurry measurements, recovered mass and corrected dimensions
Edit your enquiryRead the manufacturer dossier →
Analytics preferences

Usage analytics loads only with your consent. Private pages are excluded. Inquiry text and contact details are not sent to analytics.

Analytics has not been allowed.