ACEY-PS8 prismatic OCV and internal-resistance cell sorter

ACEY-PS8 measures open-circuit voltage and internal resistance on prismatic cells, then sorts them into seven grades plus a reject channel. Cells up to 300 mm long are loaded by hand and tested automatically, with a quoted rate of up to 1000 cells per hour. It fits incoming-cell grouping before PACK assembly.

By Xiamen Acey New Energy Technology Co., Ltd. · ACEY-PS8

BatteryEquip editorial teamSource review: 2026-10-11Buying guide based on the maker's published data.
PUBLISHED REFERENCE

Manual loading, automatic testing

ACEY's table covers cells 100–300 mm long, 20–85 mm wide and 100–300 mm high, with seven sorting grades plus NG. A PC runs the machine. The operator loads cells, and the test runs automatically; the internal-resistance tester brand is a buyer option. Ask how tested cells reach each channel and which unloading and refill tasks stay with the operator.

ACEY quotes up to 1000 cells per hour without stating the cell size, handling, test dwell or bin spread behind it. Ask for a timed cycle with the tester you will receive and your own cells. Plan for an operator at the station, and note that a bin that fills quickly adds emptying time.

Original parameter values · 7 entries
ParameterPublished valueRecord status
Sorting allocation7 grades + NG known
Cell length envelope100–300 mmknown
Cell width envelope20–85 mmknown
Cell height envelope100–300 mmknown
Compressed air requirement0.5–0.6 MPaknown
Approximate dimensions1955 × 1624 × 1596 mmknown
Approximate mass477 kgknown

Catalogue values apply to the configuration and test method the maker states. Ask for the values that apply to your configuration.

Source references: s1

BUYER NOTES

Fix the measurement conditions before you set bins

ACEY describes the machine as having 'micro-level accuracy', with no voltage or resistance specification behind it. Ask for the instrument model, ranges, accuracy, contact design, resistance test frequency or method, and calibration certificates. Your acceptance procedure should fix cell temperature, rest time, state of charge and contact cleanliness.

Set real grade thresholds and decide how cells on a boundary are graded. Include reference cells or agreed standards and repeat measurements to judge stability. ACEY says the machine handles LiFePO4 and NCM cells; each chemistry and cell design needs its own matching rule. Base the grouping policy on your module requirements.

Source references: s1

BUYER NOTES

Ask to see the MES link working

ACEY states that an MES interface is available, with data upload and SPC reports. Ask for the protocol, the record fields, how results attach to each cell ID, and what the machine does when the network drops or a cell has no readable ID. Check whether raw readings, grade decisions, tester settings and calibration version are all stored. Have the link demonstrated with your own MES before acceptance.

Listed utilities are 220 V at 50/60 Hz and air at 0.5–0.6 MPa. The machine measures about 1955 × 1624 × 1596 mm and weighs 477 kg. The page also gives a wide ambient range and a floor-load statement; ask ACEY to confirm both for the configured tester and its support points. Work from an approved site drawing, and check accuracy at the room conditions you will actually run.

Source references: s1

MAKE A SELECTION

Questions that change the purchase

DecisionWhat the catalogue saysNext step
Which tester is delivered?The tester brand is optional and the page gives no voltage or resistance accuracy.Specify the instrument, contacts, calibration and measurement procedure.
How are boundary cells classified?The page lists seven grades plus NG without thresholds.Agree bins, repeat tests and reject rules on sample cells.
Is traceability complete?The page states an MES interface with data upload and SPC reports.Demonstrate cell IDs, exported records and offline or fault behaviour.
CLEAR UP THE DETAIL

Equipment questions

Will the sorter measure cell capacity or guarantee matching life?

PS8 measures OCV and internal resistance. Capacity needs a charge/discharge test on separate equipment, and ageing or self-discharge checks may also feed your grouping. ACEY lists no capacity channels for PS8 and gives no pack-life figure.

Source s1
FROM READING TO A BRIEF

Prepare the supplier conversation

Fill in the conditions below and ask the supplier to answer each open point in writing. Copying or downloading stays in your browser; nothing is sent.

Prepare a full project brief →

SOURCES

Sources and check dates

The maker's own pages and public records used for this page, each with the date it was checked.

s1 · ACEY-PS8 prismatic OCV and internal-resistance cell sorter — manufacturer equipment page

ACEY · Manufacturer-origin source

ACEY's product page giving cell size range, grade count, loading method, rate, MES interface and utilities.

Archived source check: 2026-10-11

s2 · ACEY official equipment portfolio

ACEY · Manufacturer-origin source

ACEY's range, including the welders and testers that follow cell sorting on a pack line.

Archived source check: 2026-10-11

Still to confirm

  • The model, ranges and accuracy of the OCV and internal-resistance instrument delivered with the sorter.
  • The cells-per-hour rate with your cell size, test dwell and bin spread.
  • The MES protocol, cell identification method and behaviour when the network or an ID is missing.
  • The ambient range and floor load for the configured machine.
BEFORE YOU REQUEST A QUOTE

Prismatic-cell OCV/IR grouping with defined bins, contact measurements and data interfaces

  1. Cell envelope and terminal drawing
  2. OCV/IR instrument, ranges, accuracy and contact method
  3. Rest, SOC and temperature conditions and bin thresholds
  4. Manual handling, bin emptying and timed cycle
  5. Cell identifiers, MES records and failure recovery
  6. Site utilities and delivered calibration documents
Edit your enquiryRead the manufacturer dossier →