Prismatic Cell Capacity and Cycle Tester

The XWELL XW-5V100A64CH is a prismatic cell capacity and cycle tester, headed as 64 channels at 5 V and 100 A, with independently programmed channels and four-wire measurement. Its technical table lists 32 channels and currents up to 120 A, so ask XWELL to confirm the configuration in writing before quoting fixtures or power.

By Guangdong Xwell Technology Co., Ltd. · XW-5V100A64CH

BatteryEquip editorial teamSource review: 2026-10-11Buying guide based on the maker's published data.
PUBLISHED REFERENCE

XW-5V100A64CH: confirm channels and current first

The product heading and model number describe a 64-channel, 5 V, 100 A tester. The technical table gives 32 channels and current entries up to 120 A, and one charging range is written as 6120mA~120A. Ask XWELL to confirm the channel count, current ranges and cabinet power before you make any comparison with other testers.

XWELL describes independently programmed channels, four-wire measurement and capacity and cycle testing. It lists constant-current and constant-voltage charging, logging of voltage, current, time and capacity, and recovery of data after an interruption. These functions apply whichever electrical rating is confirmed.

Ask for a signed model specification that ties channel count, current ranges, simultaneous operation, power supply and accuracy basis to the exact cabinet. The catalogue quotes 0.05% accuracy without saying whether it is of reading or full scale, so ask for the basis and the calibration conditions.

Original parameter values · 3 entries
ParameterPublished valueRecord status
Recorded dataVoltage, current, time and capacity known
Measurement interfaceFour-wire known
Test modesCapacity separation, capacity measurement and cycle-life testing known

Catalogue values apply to the configuration and test method the maker states. Ask for the values that apply to your configuration.

Source references: s2

BUYER NOTES

Check the exported file as well as the live curve

XWELL lists text, Excel, Word and MDB export. Ask for a real output from the software version you will receive, showing channel ID, cell ID and interruption status. Confirm the recording interval and whether calculated values such as discharge efficiency follow the test definitions you use.

Four-wire measurement still needs an agreed contact fixture and cable layout. Run a typical capacity programme on your cell format with the proposed connections, then stop it in a planned, safe way and check the recovered record.

Source references: s2

BUYER NOTES

What to put in the enquiry

Send the cell format, voltage window, maximum charge and discharge currents, the number of channels that must run together and the planned cycle programme. Ask XWELL to return a corrected electrical schedule, a fixture drawing, the software version, the calibration basis and a sample data file. Shipping prices, availability and CE documents should come in a current quotation, with the CE file issued for this machine.

Buying guidance from BatteryEquip.

BUYER NOTES

Wait for the corrected figures before sizing fixtures and power

The heading says 64 channels and 100 A; the technical table says 32 channels with entries up to 120 A. Ask for a cabinet number and a corrected range table before working out electrical demand, fixture count or daily test capacity. File XWELL's answer alongside the original catalogue figures.

Once the configuration is fixed, agree simultaneous loading, the accuracy basis for voltage and current and a sample export with settings and cell IDs. Watch the tester recover from an agreed interruption and note any channels or records that must be retested. Make these points part of your acceptance plan for the tester.

Source references: s2

MAKE A SELECTION

Questions that change the purchase

DecisionWhat the catalogue saysNext step
Which channels and ranges are in the order?The heading lists 64 channels and 100 A; the table lists 32 channels and up to 120 A.Ask for a channel schedule and an explanation of the 6120mA~120A entry.
Can the data support the intended experiment?The page lists independent channels and data recovery, with no recording interval.Run your programme and check range changes, time stamps and interruption recovery.
CLEAR UP THE DETAIL

Equipment questions

Is this a 64-channel 100 A cabinet?

The heading says so, but the table differs. Confirm both figures and the cabinet layout before ordering or working out total power.

Source s2
Will the export formats work with my database?

The listing names the file formats. Check a sample file from the actual software version against your database or analysis workflow.

Source s2
FROM READING TO A BRIEF

Prepare the supplier conversation

Fill in the conditions below and ask the supplier to answer each open point in writing. Copying or downloading stays in your browser; nothing is sent.

Prepare a full project brief →

SOURCES

Sources and check dates

The maker's own pages and public records used for this page, each with the date it was checked.

s1 · Company and supply-scope record

Guangdong Xwell Technology Co., Ltd. · Manufacturer-origin source

XWELL's company overview and equipment range.

Archived source check: 2026-10-07

s2 · Prismatic Cell Capacity and Cycle Tester

Guangdong Xwell Technology Co., Ltd. · Manufacturer-origin source

Product page with the model heading, technical table, functions, accuracy figure and export formats.

Archived source check: 2026-10-07

s3 · Official portfolio context

Guangdong Xwell Technology Co., Ltd. · Manufacturer-origin source

XWELL's other testers and line equipment.

Archived source check: 2026-10-07

Still to confirm

  • The channel count (64 or 32) and current ranges (100 A or up to 120 A) of the cabinet you order.
  • The meaning of the 6120mA~120A charging range entry.
  • Whether the 0.05% accuracy is of reading or of full scale, and the calibration conditions.
  • The recording interval and a sample export from the software version supplied.
  • Current CE documents for this machine.
BEFORE YOU REQUEST A QUOTE

Capacity and cycle testing of prismatic cells

  1. Channel count and simultaneous loading
  2. Confirmed current ranges
  3. Programme and saved-data interval
  4. Recovery and export requirements
Edit your enquiryRead the manufacturer dossier →
Analytics preferences

Usage analytics loads only with your consent. Private pages are excluded. Inquiry text and contact details are not sent to analytics.

Analytics has not been allowed.