Battery Manufacturing Equipment
EQUIPMENT • CALENDERING

LDHY400-N45 laboratory electrode calender

The NAKNOR LDHY400-N45 is a laboratory roller press for electrode trials, with 400 × 450 mm rolls, 200–400 mm electrode width, a 150 T maximum working force and up to 12.5 m/min. Heated rolls are an option, so specify heating and line force for your electrode when you ask for a quote.

By NAKNOR · LDHY400-N45

BatteryEquip editorial teamSource review: 2026-10-07Buying guide based on the maker's published data.
PUBLISHED REFERENCE

LDHY400-N45 specification and options

The catalogue row lists 400 × 450 mm rollers, an electrode width of 200–400 mm, a maximum working force of 150 T and a maximum equipment speed of 12.5 m/min. The hydraulic station is standard. Heated rollers and an automatic pneumatic-hydraulic booster are optional, so name the pressure arrangement you want in the quotation.

NAKNOR describes the line as unwinding, edge trimming, dust removal, rolling and rewinding for small laboratory batches. List the auxiliaries you need and have them written into the scope. The 150 T figure is a total machine rating. Line force per unit of electrode width depends on the width you run, and the density you reach at top speed depends on your electrode.

Original parameter values · 3 entries
ParameterPublished valueRecord status
Electrode width200–400 mm known
Maximum working pressure150 T known
Maximum equipment speed12.5 m/min known

Catalogue values apply to the configuration and test method the maker states. Ask for the values that apply to your configuration.

Source references: s2

BUYER NOTES

Let your electrode set the acceptance test

Send the chemistry, polarity, width, incoming thickness and the compressed condition you need. Decide what roller temperature the electrode needs before choosing the heating option. Measure each sample at both edges and in the centre, and agree the time after pressing when thickness is read, so that relaxation is kept apart from machine variation.

During the trial, look for wrinkles, coating adhesion problems and poor rewinding. Ask for roller runout and temperature records at the proposed conditions. Floor area and patent counts on a company page tell you about the business; these machine records tell you about your result.

Buying guidance from BatteryEquip.

BUYER NOTES

Measure density and springback after the press trial

Prepare samples with the intended coating, incoming thickness and web width. Agree how final thickness and density will be measured before the supplier picks rolling settings. Log the gap, the load definition, the speed and any heating setup with each sample. Without those conditions, the result is hard to repeat on the delivered machine.

Read the agreed properties right after rolling and again after the agreed relaxation period, which shows springback. Check surface damage, coating transfer and edge behaviour on their own, apart from the average thickness. If heating is proposed, ask for a temperature mapping plan and the method used to reach the operating condition. Have the quoted total force turned into a working force for your width and roll geometry, so the trial targets the density your electrode actually needs.

Buying guidance from BatteryEquip.

MAKE A SELECTION

Questions that change the purchase

DecisionWhat the catalogue saysNext step
Can the electrode achieve the required density?The catalogue gives a 150 T total force and 12.5 m/min top speed, with no density figures.Run a trial at your width, incoming thickness and target density, with the settings logged.
Is heating specified?The table lists heated rollers as an optional item.Order the heater package by name and agree the temperature-uniformity acceptance test.
CLEAR UP THE DETAIL

Equipment questions

Is heating standard on this model?

No. The table marks heated rollers as optional. Name the heating package and the temperature-control scope in your order.

Source s2
Can 150 T be compared directly with line-load figures?

Only once the working width and roller geometry are known. Ask the supplier to state the operating force it proposes and how it spreads across your electrode.

Source s2
FROM READING TO A BRIEF

Prepare the supplier conversation

Fill in the conditions below and ask the supplier to answer each open point in writing. Copying or downloading stays in your browser; nothing is sent.

Prepare a full project brief →

SOURCES

Sources and check dates

The maker's own pages and public records used for this page, each with the date it was checked.

s1 · Company and supply-scope record

NAKNOR · Manufacturer-origin source

NAKNOR's company details and the product areas it supplies.

Archived source check: 2026-10-07

s2 · LDHY400-N45 laboratory electrode calender

NAKNOR · Manufacturer-origin source

Catalogue row for the LDHY400-N45 with roll size, width, force, speed and the standard and optional items.

Archived source check: 2026-10-07

s3 · Official portfolio context

NAKNOR · Manufacturer-origin source

NAKNOR's calender portfolio, useful for comparing the laboratory model with larger machines.

Archived source check: 2026-10-07

s4 · National standard drafting record for battery equipment

National standards information service · Public original record

Public record naming the company among the drafting organizations of a battery-equipment standard.

Archived source check: 2026-10-07

Read original record →

Still to confirm

  • The heating option and roll configuration included in the LDHY400-N45 quote.
  • The working force per unit width at your electrode width, and how it relates to the 150 T rating.
  • The density and final thickness reached on your electrode in the trial, with the settings used.
BEFORE YOU REQUEST A QUOTE

Laboratory electrode calendering for small trial batches

  1. Electrode width and incoming thickness
  2. Target density and final-thickness limits
  3. Load definition and gap control
  4. Heating option and trial record
Edit your enquiryRead the manufacturer dossier →