Battery Manufacturing Equipment
EQUIPMENT • CELL ASSEMBLY

Lithium-metal solid-state battery pilot line

Mikrouna's lithium-metal solid-state battery pilot line processes lithium-metal-anode cells in a fully sealed, ultra-dry space with dew point held below −70 °C. It is designed for lithium metal, sulfide electrolytes and other moisture-sensitive materials in development and pilot work.

By MIKROUNA

BatteryEquip editorial teamSource review: 2026-10-07Buying guide based on the maker's published data.
PUBLISHED REFERENCE

Sealed, ultra-dry processing

Mikrouna's page describes making lithium-metal-anode solid-state batteries in a fully sealed, ultra-dry space, with dew point controlled below −70 °C. It names lithium metal, sulfide electrolytes and other moisture-sensitive components as the intended materials.

The page gives no cell format, production rate or full station list. Ask for the process map: material entry, film and electrode preparation, assembly, transfer and unloading, with the atmosphere held at each step. Ask also for readings at the workpiece during loading and after an interrupted cycle, since the headline dew point describes the enclosure.

Original parameter values · 3 entries
ParameterPublished valueRecord status
EnvironmentFully sealed ultra-dry processing enclosure known
Published dew pointBelow −70 °C known
Intended inputsLithium-metal anode and moisture-sensitive solid-state battery components known

Catalogue values apply to the configuration and test method the maker states. Ask for the values that apply to your configuration.

Source references: s2

BUYER NOTES

Recovery of the atmosphere and material handover

State how sensitive your materials are, how much exposure is allowed and where measurements are needed. Ask for sensor calibration and a record from loaded operation, including transfer-door use and recovery after access. Find out how oxygen is monitored and what other controls your material needs, since dew point covers moisture only.

Pilot acceptance should name your chemistry and sample route and tie results to the enclosure records. Ask the supplier for a validated process on your sulfide or lithium-metal materials, and for equipment compliance documents for your market.

Buying guidance from BatteryEquip.

BUYER NOTES

Who controls the atmosphere at each transfer

Mark the controlled spaces, loading points and sample-transfer route on the pilot-line drawing. Ask the supplier which sensors watch each boundary, how they are checked and which records go with a material transfer. The cabinet dew point tells you little about the atmosphere around a sample during loading or unloading, so measure there too. Have qualified process and safety specialists set the requirements for your chemistry.

Ask for the operating envelope, interlock description and recovery instructions for the equipment offered. Agree a supervised acceptance of the stated controls using approved procedures and suitable test materials. Assign gloves, seals, consumables, atmosphere services and waste handling in the handover package. Qualify the chemistry as a separate task from checking the equipment functions, and run experiments only within the system limits Mikrouna approves.

Pilot cells from such a line still need formation under pressure and temperature control, as the formation and capacity grading page explains.

Buying guidance from BatteryEquip.

MAKE A SELECTION

Questions that change the purchase

DecisionWhat the catalogue saysNext step
Which atmosphere boundary is controlled?The page gives a dew point below −70 °C for the enclosure.Set oxygen and moisture measurement points and the sample-transfer route.
Who qualifies the chemistry and operation?The page describes the equipment and its intended materials only.Agree specialist-set operating limits, interlocks and handover documents.
CLEAR UP THE DETAIL

Equipment questions

Does below −70 °C describe every operating condition?

No. It is Mikrouna's catalogue target. Ask for readings at defined sensor positions during loading, processing and recovery, with allowed excursions written down.

Source s2
Does the government report validate the pilot-line output?

No. It describes glovebox manufacturing and the company's business direction. Plan a cell-process trial and an acceptance schedule for this line.

Source s4
FROM READING TO A BRIEF

Prepare the supplier conversation

Fill in the conditions below and ask the supplier to answer each open point in writing. Copying or downloading stays in your browser; nothing is sent.

Prepare a full project brief →

SOURCES

Sources and check dates

The maker's own pages and public records used for this page, each with the date it was checked.

s1 · Company and supply-scope record

MIKROUNA · Manufacturer-origin source

Mikrouna's company overview of its enclosure and battery-equipment business.

Archived source check: 2026-10-07

s2 · Lithium-metal solid-state battery pilot line

MIKROUNA · Manufacturer-origin source

The product page describing the sealed ultra-dry process, dew-point target and intended materials.

Archived source check: 2026-10-07

s3 · Official portfolio context

MIKROUNA · Manufacturer-origin source

Mikrouna's gloveboxes and other battery-line equipment.

Archived source check: 2026-10-07

s4 · Jinshan production report on MIKROUNA

Shanghai government · Public original record

A Shanghai government report on Mikrouna's glovebox production and its solid-state plans.

Archived source check: 2026-10-07

Read original record →

Still to confirm

  • The dew point at the workpiece during loading, transfer and recovery.
  • Oxygen monitoring and other controls for your materials.
  • The process stations included and accepted cell output on your chemistry.
  • Equipment compliance documents for your market.
BEFORE YOU REQUEST A QUOTE

Sealed dry-atmosphere pilot line for lithium-metal cells

  1. Chemistry and process route
  2. Atmosphere and transfer boundaries
  3. Measurement and interlock acceptance
  4. Qualified operating and maintenance procedures
Edit your enquiryRead the manufacturer dossier →
Analytics preferences

Usage analytics loads only with your consent. Private pages are excluded. Inquiry text and contact details are not sent to analytics.

Analytics has not been allowed.