Battery Manufacturing Equipment
EQUIPMENT • FORMATION & TESTING

Hangke prismatic power/storage DCIR test family

Hangke makes two DCIR testers for prismatic cells. The power-cell version tests whole or half trays with automatic loading and traceability, and lists 5 V/800 A. The storage-cell version offers 600/800/1000 A output, conveyor links, active testing, water-cooled temperature control and MES upload. Both measure direct-current resistance after formation.

By Zhejiang Hangke Technology Incorporated Company

BatteryEquip editorial teamSource review: 2026-10-11Buying guide based on the maker's published data.
PUBLISHED REFERENCE

Power-cell and storage-cell ratings

The power-cell version lists 5 V/800 A in a field labelled test current. Ask Hangke to confirm the voltage and current meaning and whether 800 A is a pulse or continuous figure, and per channel or shared. Hangke also lists whole-tray and half-tray testing, automatic loading, testing and traceability.

The storage-cell version offers 600/800/1000 A output, automatic conveyor links, active testing, water-cooled temperature control and MES upload. It gives no voltage rating, pulse length or number of channels pulsing at once. Ask for the voltage that goes with each current option. These are DCIR pulse figures; ACIR needs its own specification. Choose your terminal and tray drawing and hardware layout first.

Original parameter values · 2 entries
ParameterPublished valueRecord status
Power-cell combined voltage/current statement5 V / 800 A known
Storage output-current configurations600 / 800 / 1000 Aknown

Catalogue values apply to the configuration and test method the maker states. Ask for the values that apply to your configuration.

Source references: s1 s3

BUYER NOTES

Pulse recipe, SOC and temperature

Specify the current pulse, rest period, voltage sampling windows, resistance calculation and state of charge. Set the cell temperature before the pulse and the temperature conditions during repeat tests. Neither page gives these values, and a fair comparison between bids depends on them. Fix one DCIR recipe in the order.

Ask for the sensing and contact design and a plan for catching shifted or poor contacts. Trial representative cells in the chosen tray positions with calibrated references, and agree an uncertainty and repeatability check. Include a poor-contact case approved by Hangke. Check whole-tray and half-tray running against your real occupied positions and channels.

Source references: s1 s3

BUYER NOTES

Records, NG decisions and cooling

Define what each record keeps: cell, tray and channel IDs, pulse settings, raw samples where available, calculated resistance, and recipe and calibration version. State which system makes the NG decision and whether this station or a separate handler removes the cell. Agree data-version rules and how incomplete results are held, since the pages mention MES upload only.

Specify water-cooling services for the storage version and heat and power limits under simultaneous load for both. Using safe procedures, interrupt a test and an upload, and check that an incomplete result is held and never attached to the next tray. At handover, cover contacts, calibration, electrical isolation and who restarts the station. Ask Hangke for its pulse recipe, precision figure and good-cell rate in writing.

Hangke's profile lists its cylindrical 46XX DCIR station for comparison, and the formation and capacity grading page shows how DCIR results combine with grading data.

Source references: s1 s3

MAKE A SELECTION

Questions that change the purchase

DecisionWhat the catalogue saysNext step
How is 5 V/800 A defined?The page shows 5 V/800 A in a field labelled test current.Confirm voltage, pulse, concurrency and the configuration it applies to.
Which conditions define comparable DCIR?The pages give no SOC, rest, temperature or sampling windows.Approve a recipe and a repeat-measurement plan across channels.
Who performs physical rejection?The pages describe testing and upload but no NG removal.Define who decides and how the downstream handler confirms.
FROM READING TO A BRIEF

Prepare the supplier conversation

Fill in the conditions below and ask the supplier to answer each open point in writing. Copying or downloading stays in your browser; nothing is sent.

Prepare a full project brief →

SOURCES

Sources and check dates

The maker's own pages and public records used for this page, each with the date it was checked.

s1 · Hangke prismatic power/storage DCIR test family original public data

Hangke Technology · Manufacturer-origin source

Describes the power-cell DCIR tester with whole or half trays and the 5 V/800 A entry.

Archived source check: 2026-10-11

s2 · Hangke original post-processing equipment portfolio

Hangke Technology · Manufacturer-origin source

Shows the DCIR testers among Hangke's cell test equipment.

Archived source check: 2026-10-11

s3 · Hangke prismatic power/storage DCIR test family original public data

Hangke Technology · Manufacturer-origin source

Describes the storage-cell DCIR tester with 600, 800 or 1000 A options, water cooling and MES upload.

Archived source check: 2026-10-11

Still to confirm

  • What the 5 V/800 A field means: voltage, pulse or continuous current, per channel or shared.
  • The voltage rating for each storage current option.
  • The DCIR pulse recipe and measurement uncertainty.
  • Good-cell rate for your tray layout.
BEFORE YOU REQUEST A QUOTE

DCIR testing of prismatic power and storage cells

  1. Terminal drawing, whole or half-tray layout and contacts
  2. Chosen voltage and current, pulse length and concurrency
  3. SOC, rest, temperature and voltage-sampling method
  4. Reference checks, poor-contact handling and uncertainty
  5. Cooling and power services and simultaneous-load limits
  6. MES record format, NG hand-off and recovery
Edit your enquiryRead the manufacturer dossier →
Analytics preferences

Usage analytics loads only with your consent. Private pages are excluded. Inquiry text and contact details are not sent to analytics.

Analytics has not been allowed.