Geesun OCV, resistance and temperature tray-test station

Geesun's OCV station tests cell voltage, internal resistance and temperature on two trays, in 2×12,2×10 or 2×8 channel layouts. It has built-in zeroing and master-reference positions. Geesun lists ±0.01%rdg ±3dgt for voltage, ±0.5%rdg ±10dgt for resistance and ±0.5 °C for temperature. It suits post-formation and ageing checks.

By Shenzhen Geesun Intelligent Technology

BatteryEquip editorial teamSource review: 2026-10-11Buying guide based on the maker's published data.
PUBLISHED REFERENCE

Accuracy figures, channel layouts and probes

Voltage accuracy is printed as±0.01%rdg ±3dgt and internal resistance as±0.5%rdg ±10dgt. Each figure has a reading part and a digit part. Ask Geesun for the instrument ranges and digit resolution so you can turn them into absolute µV and µΩ limits, and ask for the resistance frequency, excitation and method as well.

The tray and channel layouts are 2×12,2×10 or 2×8. Probe life is≥300000 operations, and a test-probe row reads 89–252 mm without saying what that length describes. Ask for a probe drawing showing the geometry, contact travel or other dimension it refers to. Confirm the cell sizes your trays need and the full station cycle time in the quotation.

Original parameter values · 4 entries
ParameterPublished valueRecord status
Dual-tray channel configurations2×12 /2×10 /2×8 known
Original voltage accuracy expression±0.01%rdg ±3dgt known
Original resistance accuracy expression±0.5%rdg ±10dgt known
Listed cell-temperature contact time≤50 sknown

Catalogue values apply to the configuration and test method the maker states. Ask for the values that apply to your configuration.

Source references: s1

BUYER NOTES

Tray positioning, probe wiring and reference checks

Geesun describes secondary tray positioning, linear modules that move and press the probes, and non-metallic probe wiring to cut electrical interference. Send your tray, terminal and contact drawings, and ask for contact repeatability and poor-contact detection on the offered fixture. Check noise on your own cells during the trial.

The zero and master-reference positions allow one-button zeroing and calibration. Specify reference traceability, range and check interval. Agree what happens when a check fails: whether production stops, earlier records are flagged or cells are retested. Plan a separate comparison of every installed channel against calibrated standards at acceptance.

Source references: s1 s2

BUYER NOTES

Temperature contact time and the full tray cycle

Ambient temperature is measured to±0.5 °C. A separate cell-temperature row also gives±0.5 °C with a contact time of≤50 s, and Geesun mentions tooling for the temperature-wiring sequence. Ask for the sensor design, the settling rule and which measurements run at the same time. Contact can take up to 50 seconds, so ask how that fits into the total tray time.

At acceptance, compare electrical results at a set cell temperature, state of charge and rest time, and keep cell, tray and channel identity with each result. Watch a failed zero or reference check, a poor contact and an interrupted cycle handled by Geesun's procedure. Keep invalid readings and retests apart from cell rejects. At handover, get the tray layout, instrument settings, probe replacement and check routine, and the full load, test and unload timing. Capacity grading and the link to your data system are separate scope items.

OCV readings here feed the aging and grading decisions described on the formation and capacity grading page.

Source references: s1

MAKE A SELECTION

Questions that change the purchase

DecisionWhat the catalogue saysNext step
What absolute uncertainty follows from the mixed terms?Accuracy is given as a percentage of reading plus digits, with no range or resolution.Approve the combined figure and compare channels against calibrated standards.
What does 89–252 mm refer to?The probe row gives 89–252 mm without saying what it measures.Review probe and tray drawings and run a contact trial.
How does temperature measurement fit the cycle?The table lists ≤50 s contact time and no tray cycle time.Time electrical and temperature tests together and count good trays.
FROM READING TO A BRIEF

Prepare the supplier conversation

Fill in the conditions below and ask the supplier to answer each open point in writing. Copying or downloading stays in your browser; nothing is sent.

Prepare a full project brief →

SOURCES

Sources and check dates

The maker's own pages and public records used for this page, each with the date it was checked.

s1 · Geesun OCV, resistance and temperature tray-test station original rendered equipment description

Geesun · Manufacturer-origin source

Gives the channel layouts, voltage, resistance and temperature accuracy, probe life and reference functions.

Archived source check: 2026-10-11

s2 · Official process-specific equipment catalogue

Geesun · Manufacturer-origin source

Places the OCV station among Geesun's formation and testing equipment.

Archived source check: 2026-10-11

Still to confirm

  • Instrument ranges and digit resolution, giving absolute voltage and resistance limits.
  • The resistance test method and frequency.
  • What the 89–252 mm probe row refers to.
  • Temperature settling time and the full load, test and unload cycle.
  • How results pass to your data system.
BEFORE YOU REQUEST A QUOTE

Tray-based OCV, internal resistance and cell temperature testing

  1. Cell, tray and terminal drawing and dual-tray channel layout
  2. Instrument ranges, resolution and combined uncertainty
  3. Resistance method and frequency, SOC, temperature and rest conditions
  4. Probe dimension, poor-contact detection and replacement checks
  5. Zero and master references, intervals and failed-check handling
  6. Temperature settling, parallel tests and full station cycle
Edit your enquiryRead the manufacturer dossier →