The AOT-PVM-10L is a double planetary mixer for laboratory and pilot electrode slurry. It has a 14 L design vessel with 10 L effective volume, revolution of 0–50 rpm, rotation of 0–100 rpm, a rotary-vane vacuum pump and electric lifting, and suits medium- to high-viscosity mixtures.

By Xiamen AOT Battery Equipment Technology Co., Ltd. · AOT-PVM-10L

BatteryEquip editorial teamSource review: 2026-10-11Buying guide based on the maker's published data.
PUBLISHED REFERENCE

AOT-PVM-10L: a ten-litre effective volume

AOT lists a 14 L design vessel with 10 L effective volume. The machine combines planetary stirring and dispersion for medium- to high-viscosity mixtures. Revolution runs at 0–50 rpm and rotation at 0–100 rpm. Keep both figures in view when comparing how the mixing tools move, since a single speed headline misses half the action.

The material-contact vessel layers and the two twist-type mixing blades are 304 stainless steel. The listed package includes a rotary-vane vacuum pump, a vacuum buffer and electric lifting. Ask which wetted seals, discharge fittings and external temperature-control items come with your configuration.

Lifting and mixing are interlocked. The mixer will not stir while the vessel rises, and the vessel cannot be raised or opened during mixing. Ask AOT to show both responses on the controls you are buying, and plan the safety assessment of the full laboratory installation as your own step.

Original parameter values · 3 entries
ParameterPublished valueRecord status
Mixing volume10 Lknown
Contact material304 stainless steel known
Mixing speed0..100 rpmknown

Catalogue values apply to the configuration and test method the maker states. Ask for the values that apply to your configuration.

Source references: s2

BUYER NOTES

Cleaning and discharge are part of formulation work

The product page describes a bottom discharge valve, smooth contact surfaces and construction that opens for cleaning. For formulation work, ask how much slurry stays behind after discharge and which parts come off between batches. Agree which cleaning fluids the wetted parts tolerate, and check how much of a representative batch actually reaches the coater.

For a trial, send AOT your solids content, viscosity range and addition order. Log the revolution and rotation settings and the temperature history. Dispersion quality for your formulation comes from that trial, since geometry and motor data alone cannot predict it.

Buying guidance from BatteryEquip.

BUYER NOTES

Cooling connections and blade clearances

The updated table gives an internal vessel of 300 mm diameter by 200 mm, inner and outer SUS304 layers of 5 mm and 4 mm, and DN25 quick connections for cooling-water inlet and outlet. No heat-removal duty or cooling flow is listed. Specify your chilled-water supply and log slurry temperature through a representative mixing sequence.

Blade-to-blade, blade-to-bottom and blade-to-wall clearances are each given as an optional reference of 5 ±2.5 mm. Ask for the delivered tool geometry and tolerances that suit your formulation. The mixing motor is rated 2.2 kW. If you need high-speed dispersion under load, request the exact dispersing assembly and control setup in the quotation.

Source references: s2

BUYER NOTES

Pump, discharge recovery and vessel access

The table specifies a 0.55 kW rotary-vane pump with a vacuum buffer and a DN32 bottom valve. It gives no loaded vacuum level or leak rate. Ask for the pressure reference, the gauge and the pumping sequence, then check air removal and the recovered slurry mass on your real working charge.

Electric screw lifting has its own 0.55 kW drive, a lifting height up to 300 mm, and positioning and locking. The page says the lift stops at its travel limits, mixing is blocked while lifting, and the vessel stays closed while running. Installation figures are 380 V three-phase 50 Hz, about 3 kW total, 1400 ×810 ×1700 mm and approximately 800 kg. Leave room for service and for the raised vessel, beyond the closed footprint.

Source references: s2

BUYER NOTES

About the published citation

A published study names the AOT battery-equipment company as its supplier of sodium chips. It is a materials purchase and says nothing about this mixer. Ask AOT for the actual maker of the quoted unit and its current compliance documents.

Buying guidance from BatteryEquip.

BUYER NOTES

Record discharge yield and cleaning with the mixing result

Agree a working charge inside the 10 L effective volume, with the formulation, addition order and mixing endpoints set by your process. The 14 L figure is the vessel's design size. Ask for a trial record that names the vessel, tools, vacuum setup and settings.

After the trial, weigh the usable slurry that discharges and note what stays on the tools, seals and fittings. Where contamination matters, include cleaning access and a repeat batch. Your trial is the only source for dispersion, vacuum and cleaning results on this machine.

A ten-litre batch goes straight to coating, so read the coating width page alongside this one when you plan the trial.

Source references: s1 s2 s4

MAKE A SELECTION

Questions that change the purchase

DecisionWhat the catalogue saysNext step
Is the requested batch within the effective capacity?The catalogue gives 10 L effective volume and 14 L design volume.State your fill, viscosity and usable batch size in the enquiry.
What remains after changeover?The page lists a bottom valve and cleanable surfaces but no cleaning time or residue figure.Agree a cleaning demonstration and sample checks before the next formulation.
CLEAR UP THE DETAIL

Equipment questions

Is the design vessel size the usable batch size?

No. The vessel is 14 L by design and 10 L effective. Plan your working charge and addition sequence against the 10 L figure.

Source s2
Do the lifting interlocks cover laboratory safety?

They are machine functions that AOT describes. Test them at acceptance, and assess the wider installation's safety requirements on their own terms.

Source s2
FROM READING TO A BRIEF

Prepare the supplier conversation

Fill in the conditions below and ask the supplier to answer each open point in writing. Copying or downloading stays in your browser; nothing is sent.

Prepare a full project brief →

SOURCES

Sources and check dates

The maker's own pages and public records used for this page, each with the date it was checked.

s1 · Company and supply-scope record

Xiamen AOT Battery Equipment Technology Co., Ltd. · Manufacturer-origin source

AOT's company description, including its workshop and use of subcontracting factories.

Archived source check: 2026-10-07

s2 · AOT-PVM-10L Double Planetary Mixer

Xiamen AOT Battery Equipment Technology Co., Ltd. · Manufacturer-origin source

The product page with the 10 L effective and 14 L design volumes, utilities, blade clearances and lifting functions.

Archived source check: 2026-10-11

s3 · Official portfolio context

Xiamen AOT Battery Equipment Technology Co., Ltd. · Manufacturer-origin source

AOT's product range, useful for seeing which coaters and ovens pair with the mixer.

Archived source check: 2026-10-07

s4 · 2025 sodium-oxygen electrolyte study: AOT material-supply reference

Europe PMC / EMBL-EBI full text of the published paper · Public original record

The methods section lists Xiamen AOT Battery Equipment Technology Co. as the source of the sodium chips used.

Archived source check: 2026-10-11

Read original record →

Still to confirm

  • The actual manufacturer of the quoted mixer and the contracting company.
  • The loaded vacuum level and leak rate for the supplied pump and buffer.
  • The delivered blade clearances and dispersing assembly for your formulation.
  • Discharge yield, residue and cleaning time measured on your working charge.
  • The cooling flow needed to hold slurry temperature through your mixing sequence.
BEFORE YOU REQUEST A QUOTE

Ten-litre planetary slurry mixing for laboratory and pilot work

  1. Recipe and viscosity range
  2. Effective batch fill
  3. Discharge and residue limits
  4. Changeover and cleaning acceptance
  5. Cooling supply, slurry-temperature log and delivered blade clearances
  6. Vacuum pressure reference, pump and buffer, and leak-test method
  7. DN32 discharge recovery, lift access and interlock demonstration
Edit your enquiryRead the manufacturer dossier →
Analytics preferences

Usage analytics loads only with your consent. Private pages are excluded. Inquiry text and contact details are not sent to analytics.

Analytics has not been allowed.